When the internal controller detects a PA temperature of greater than 90 degrees C, the RF output power will
completely shutdown, and the HIGH TEMP LED will flash red at a rate of twice a second. The RF output power will
stay shutdown until the PA temperature has dropped below 65 degrees C. When the internal controller detects that the
PA temperature is below 65 degrees C, it will turn off the HIGH TEMP LED and then enable the PA to transmit power.
A HIGH TEMP alarm could be due to the fan malfunctioning, the SRPT-40A placed in a closed-in area with limited
air circulation, or an experience of high VSWR.
HIGH VSWR LED
When the internal controller detects a VSWR of greater than 2 but less than 4, the HIGH VSWR LED will flash red
at a rate of once per second.
When the internal controller detects a VSWR of greater than 4, the output power will limit to a maximum of 25
Watts and the HIGH VSWR LED will flash red at a rate of twice per second. When the detected VSWR falls less than 4,
the output will resume to it's previous power setting (if the setting was greater than 25 Watts before going into power
fold-back), the HIGH VSWR LED will flash at a rate of once per second if VSWR greater than 2, and will turn off if
VSWR is less than 2.
METER and METER SELECT Knob
When the METER SELECT Knob is either in the FORWARD POWER or REVERSE POWER position, the
corresponding measurement can be read off of the top "WATTS" scale of the METER.
When the METER SELECT knob is either in the PA CURRENT or the B+ position, the corresponding
measurement can be read off of the middle "VOLTS/AMPS" scale of the METER.
When the METER SELECT knob is in the AUDIO COMPRESSION position, the corresponding measurement can
be read off of the bottom "VU" scale of the METER.
MIC Input Connectors
These balanced inputs are for a 150 ohm dynamic microphone such as the Shure BG 1.0 with standard XLR-3 or
A3M connector. Microphone connections are given in INSTALLATION.
Input 4 can operate at MIC LEVEL or HIGH LEVEL by means of a SELECTOR switch inside the transmitter just
behind the Input 4 pot. The unit is factory selected for "HI" (HIGH) LEVEL balanced input for use with tape machines,
etc. To convert Input 4 to MIC (microphone) LEVEL, remove top cover and move switch to "MIC".
MONITOR Jack
The MONITOR jack is active in "STANDBY" and "TRANSMIT" positions of the TRANSMIT/STANDBY
switch. A high-quality headset having 300 ohms or higher impedance can be plugged into the MONITOR jack to make
adjustments or to monitor the quality of the audio being transmitted. A miniature, single circuit, 1/8 inch, phone plug
should be used with the MONITOR jack.
POWER ADJUST Pot
When the SRPT-40A is transmitting, this pot can be adjusted to increase or decrease the output power from the
MAXIMUM power setting to almost zero Watts.