  • Page 1 MARTI ELECTRONICS RPU TRANSMITTER MODELS: SRPT-30 SRPT-40A...
  • Page 2 8/7/2003 RF EXPOSURE WARNING This remote pickup unit (RPU) contains a radio frequency (RF) transmitter. During normal operation it sends out radio frequency (RF) signals. In August 1996, the Federal Communications Commission (FCC) adopted RF exposure guidelines with safety levels for wireless devices. CAUTION: To maintain compliance with the FCC’s RF exposure guidelines, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 6 meters from all persons during normal...
  • Page 3: Limited Warranty

    3rd printing, January 2003 No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system , or translated into any language, natural or computer, in any form or by any means, without the prior written permission of Marti Electronics.
  • Page 4 Information in this manual is subject to change without notice and does not represent a commitment on the part of Marti Electronics. Marti Electronics may make improvements and/or changes in this manual or in the product described herein at any time. This product could include technical inaccuracies or typographical errors.
  • Page 5: About This Manual

    8/7/2003 ABOUT THIS MANUAL This manual supports both the SRPT-30 and SRPT-40A RPU transmitters for all standard (and some non- standard) frequency bands. The SRPT-30/40A in some frequency bands may not yet be available during the printing of this manual. The manual will be revised as new frequency bands become available.
  • Page 6: Table Of Contents

    Drawing 702-117 “SRPT-30/40A RF Systems & Control”......... Recommended Test Equipment ………………………………………………………… Tools For Alignment ……………………………………………………………………. 36 SRPT-30/40A Transmitter Factory Test Report …………………………………...…… Calibration and Adjustments …………………..............38 Drawing 702-122 “SRPT-30/40A Adjustment Locations”……………………..…… SRPT-30/40A Bill of Material and Schematics ……………..........51...
  • Page 7: Introduction

    8/7/2003 INTRODUCTION See the SPECIFICATIONS & ORDERING section for a listing of available frequency ranges and power models. SRPT-30 DUAL-CHANNEL RPU TRANSMITTER SRPT-40A FREQUENCY AGILE RPU TRANSMITTER...
  • Page 8 The Marti Models SRPT-30/40A are wide-band – high power RPU Transmitters designed to operate in the Remote Pick-Up Broadcast Service as defined in Part 74, Subpart D, of the FCC Rules and Regulations. The SRPT-30 replaces the Marti RPT-30 series of RPU’s. Like its predecessor, the SRPT-30 has two frequency channels and a four-input mixer for mic/line audio.
  • Page 9 Remembers and locks-on last frequency during power-up · Frequency resolution: 5 or 6.25 KHz steps – ± .00004% accuracy - Most other frequencies (100 Hz steps) - ± .00015% accuracy SRPT-30 Only Features: · Continuous-duty output - 30 watts maximum most models ·...
  • Page 10: Specifications & Ordering

    Accuracy operate within model frequency range and will have an accuracy within: SRPT-30 (450 models and less) (1) ± .00004% for frequency divisible by 5 or 6.25 KHz, or (2) ± .00015% for MOST frequencies NOT divisible by 5 or 6.25 KHz*...
  • Page 11 External DC operation on 12 - 15 volts or 15 - 30 volts. Approximate PA Current SRPT-40A: 8.5 to 10.5 Amps Rating (at maximum power SRPT-30: 6.5 to 7.5 Amps output): (The data above varies across frequency band and from model to model) Accessory Connector: 15-pin D connector for DC power, remote control, encode, line level input.
  • Page 12: Ordering Information

    Description 585-141 12-15 VDC External Supply Cable 585-142 15-30 VDC External Supply Cable 585-139 12-15 VDC Mobile Repeat Cable, CR/AR-10 to SRPT-30/40A 585-140 15-30 VDC Mobile Repeat Cable, CR/AR-10 to SRPT-30/40A 585-143 Fixed Repeat Cable, CR/AR-10 to SRPT-30/40A 700-250-13 Rack mounting kit...
  • Page 13: Unpacking And Inspection

    8/7/2003 UNPACKING & INSPECTING This equipment was factory tested, inspected, packed, and delivered to the carrier with utmost care. Do not accept shipment from carrier which shows damage or shortage until the carrier's agent endorses a statement of the irregularity on the face of the carrier's receipt. Without documentary evidence, a claim cannot be filed.
  • Page 14: Installation

    Stationary Remote Broadcast Installation The basic stationary remote installation consists of the SRPT-30/40A transmitter, a 110-120 or 220-240 VAC power source, microphones and other audio program sources, and a portable antenna. Remotes using portable antennas inside buildings have very limited range (typically less than one mile). If greater range is needed, consider locating the transmitting antenna outside the building at a height necessary to provide a line-of-sight path to the receiving antenna.
  • Page 15 8/7/2003 With the SRPT-30/40A TRANSMIT/STANDBY switch in “STANDBY” position, plug the transmitter into a grounded, three-prong, 110-120 or 220-240 VAC outlet. WARNING THE MANUAL SWITCH ON THE INTERNAL SWITCHING POWER SUPPLY IS SET AT THE FACTORY TO THE 115 POSITION IF THE ORDER WAS FOR 110-120 VAC.
  • Page 16: Transmitter Mounting

    MICROPHONE, ANTENNA, OR OTHER CONNECTED EQUIPMENT) ARE STANDING ON WET GROUND OR CONCRETE. For locations where AC power is not available, the SRPT-30/40A can be powered from a fully charged automobile battery. Connect a portable antenna such as the Marti PAV/150, PAV-450, or YC-450 to the ANTENNA connector on the back of the transmitter.
  • Page 17 SRPT-30/40A Mobile Remote Control Remote control of the SRPT-30/40A transmitter requires a switch to control primary 12-15 VDC power (or 15-30 VDC) and a second switch to control the transmit function. The primary 12-15 VDC (or 15-30 VDC) control requirement can be met by tapping the ignition switch circuitry of the vehicle. The “transmit” function can be performed by installing a switch on the vehicle.
  • Page 18 8/7/2003 this system. Along with the data, a station identifier in morse code can also be input into the TSL. Marti typically uses the RACOM MODEL 1402 Automatic Morse Code Station Identifier to accomplish this task. Marti stocks and sells the RACOM 1402 (part number 565-006-1) along with the interconnecting cable (part number 585-088).
  • Page 19 8/7/2003...
  • Page 20 8/7/2003...
  • Page 21 FAILURE TO USE A PROPERLY GROUNDED OUTLET COULD RESULT IN A SAFETY HAZARD OR FAULTY EQUIPMENT PERFORMANCE. For fixed automatic repeater operation, connect Cable No. 585-143 (FIG. 4.) between accessory connectors of the receiver and SRPT-30/40A transmitter. Connect receiving antenna to receiver J6 and transmit antenna to SRPT- 30/40A ANTENNA connector.
  • Page 22: Antennas

    BASE STATION ANTENNA INSTALLATION CHECKLIST The following suggestions are offered to help those responsible for antenna installations avoid costly errors in assembly and adjustment. Marti Electronics assumes no responsibility for the installation and performance of antenna systems associated with its equipment. The following suggestions are not intended to be a complete step-by-step procedure, simply a listing of some of the most frequently reported errors in antenna system installation.
  • Page 23 8/7/2003 System Grounding It is essential that the RPU antenna system be properly grounded for safety and proper operation. Antenna Installation and Adjustment The polarization of the transmit and receive antennas of the RPU system must be the same! This means that if the transmitting antenna is vertical, the receiving antenna must also be vertical.
  • Page 24: Control, Led, & Connector Functions

    External DC supply: The SRPT-30/40A can be powered externally by either a 12-15 Volt DC supply or a 15-30 Volt supply. If powered off a 12-15 Volt supply, connect three positive leads of the supply to pins 6, 7, and 14. Connect three negative leads of the supply to three ground pins (pins 1, 11, and 12).
  • Page 25 SUPPLY. AC LINE Switch, AC Receptacle & Fuse When the transmitter is not in use or if the SRPT-30/40A is to run off of an external supply, the AC LINE switch should be in the “OFF” position. When ready to use the SRPT-30/40A off of the AC line voltage, plug power cord into the AC Receptacle and switch the AC LINE switch to the “ON”...
  • Page 26 FREQUENCY SELECT pushwheel switches to the internal controller to be decoded and executed. See the OPERATION section for a listing and understanding of all commands. F1/F2 Switch (SRPT-30 only) Switching to the F1 position will cause the transmitter to lock onto the frequency that was configured at the factory as “F1”.
  • Page 27 PA temperature is below 85 degrees C, it will turn off the HIGH TEMP LED and then enable the PA to transmit power. A HIGH TEMP alarm could be due to the fan malfunctioning, the SRPT-30/40A placed in a closed-in area with limited air circulation, or an experience of high VSWR.
  • Page 28 A miniature, single circuit, 1/8 inch, phone plug should be used with the MONITOR jack. POWER ADJUST Pot When the SRPT-30/40A is transmitting, this pot can be adjusted to increase or decrease the output power from the MAXIMUM power setting to almost zero Watts. TRANSMIT LED When the TRANSMIT/STANDBY switch is in the STANDBY position, the SRPT-30/40A will not transmit and the TRANSMIT LED will be off.
  • Page 29: Operation

    External DC Supply (12-15 Volt) Operation Make sure that the SRPT-30/40A is not connected to an AC line. Place the front panel AC LINE switch in the ON position. This turns off External DC Supply (12-15 Volt) to the unit.
  • Page 30 12 and 15 VDC. The unit should power up. From 16 to 20 VDC, the SRPT-30/40A will transmit up to 50 Watts RF output. From 20 to 30 VDC the SRPT-40A maximum output power will derate linearly down to 20 watts.
  • Page 31 Power-Up SRPT-30/40A If using AC line, turn on SRPT-30/40A by turning on front panel AC LINE switch. If using 12-15 Volt or 15-30 Volt external DC supply, turn on SRPT-30/40A by turning on external DC supply. Refer to the External DC Supply Operation procedure above for proper installation and operation.
  • Page 32: Inputting Audio

    SRPT-30 Only: The SRPT-30 will power-up on frequency F1 or F2 depending on the position of the F1/F2 front panel switch. The frequencies corresponding to F1 and F2 were determined at the time of order and are hard coded within the synthesizer.
  • Page 33 450 band models. All other frequencies are considered non-standard frequencies. The SRPT-30/40A will lock on standard output frequencies within a ±.00004% tolerance. The SRPT-30/40A will lock on about 95% of non- standard frequencies. The tolerance of these frequencies fall within ±.00015% of the requested frequency. If the synthesizer determines that the non-standard frequency will fall outside ±.00015% of the requested frequency, then this...
  • Page 34 8/7/2003 Changing Output Frequency via Channel Select – SRPT-40A Only The frequency can also be changed by entering a channel number that was previously stored with a frequency. See Storing Output Frequencies into Channels for instructions on how to store frequencies. There are ten channels available for storing and recalling frequencies.
  • Page 35 8/7/2003 It would be a good idea to test the stored channel(s) by changing the frequency to some other frequency and then recalling the stored channel(s). Control Switch Settings – SRPT-40A Only Control Switch Settings enable or disable important controls used in the SRPT-40A. These control settings include the following: Power Adjust Pot HiHi VSWR Foldback...
  • Page 36 8/7/2003 setting is useful for locking out anyone from changing frequencies, or to change frequencies via user programmed channels. Channel Frequency Change – The default for this setting is “enabled” to be able to change the output frequency by channel select. If “disabled”, then attempting to change the output frequency by selecting channels will be ignored by the internal controller.
  • Page 37: Theory Of Operation

    10.0 volts to the audio and mixer boards. Therefore, the synthesizer will stay locked during most power surges and excessive voltage drops. The 800-392A also suppresses any external (or internal) voltage noise such as an alternator from a running vehicle. As a result, the SRPT-30/40A still maintains a high signal-to-noise. TRANSMITTER SYNTHESIZER Board, 800-375AT The fundamental purpose of this board is to accomplish two things: (1) Generate the final output frequency and (2) FM modulate the mixed audio.
  • Page 38 The output of T2 is fed into the final PA module (U3) for an output of up to 60 Watts max. This PA module usually has a lower RF output for SRPT-30’s. The signal is then low-passed filtered through FL1 and then fed through a directional coupler for monitoring forward and reflected power.
  • Page 39 8/7/2003 RF SYSTEM & CONTROL Refer to Block Diagram Drawing 702-117. The fundamental RF generation of the SRPT-30/40A takes place on the TRANSMITTER SYNTHESIZER board in a circuit known as a Phased-Locked Loop (PLL). The final output frequency (Fout) is generated by the Voltage Controlled Oscillator (VCO). Fout is determined by the Reference Frequency (Fr) and N by the relation: Fout = Fr x N.
  • Page 40: Drawing 702-124 "Srpt-30/40A Functional Block Diagram

    8/7/2003...
  • Page 41: Drawing 702-117 "Srpt-30/40A Rf Systems & Control

    8/7/2003...
  • Page 42: Recommended Test Equipment

    8/7/2003 RECOMMENDED TEST EQUIPMENT Distortion Analyzer Krohn-Hite Model 6801 Oscillator Krohn-Hite Model 4500 Attenuator Set Hewlett-Packard Model 3500 Frequency Counter Hewlett-Packard Model 5383A (option 001) Digital Multimeter Beckman Model 3030 Analog Multimeter Triplett Model 630 RF Attenuator adjustable 0-110 dB RF Signal Generator Marconi Model 2022C Spectrum Analyzer...
  • Page 43: Srpt-30/40A Transmitter Factory Test Report

    8/7/2003 SRPT-30/40A TRANSMITTER FACTORY TEST REPORT Customer: ________________________ Address: _______________________________________ Serial No.: __________ _______________________________________ ____Set internal switching power supply = 13.0 Volts ____Program synthesizer ____Frequency measurement, adjust, and changing ____Forward power calibration and metering ____Reverse power calibration and metering ____Current metering calibration...
  • Page 44: Calibration And Adjustments

    Laboratory grade test equipment is required and is listed under TEST EQUIPMENT AND TOOLS. For location of adjustments and test points in the SRPT-30/40A Transmitter refer to Adjustment Location Diagram, 702-122. NOTE FOR ALL ADJUSTMENTS, REMOVE THE TOP COVER FROM THE SRPT-30/40A CHASSIS.
  • Page 45 THIS ADJUSTMENT HAS BEEN SET AT THE FACTORY AND SHOULD NOT REQUIRE ANY FURTHER ADJUSTMENTS. Remove AC line voltage from SRPT-30/40A. Connect up external supply to the 15-30VDC pins of the AUXILLARY connector (see the ACCESSORY Input Connector paragraph in the CONTROL & CONNECTOR FUNCTIONS section).
  • Page 46 IT IS NOT RECOMMENDED TO PERFORM THE FORWARD POWER CALIBRATION JUST TO ADJUST THE FRONT PANEL METER - FORWARD POWER. With the SRPT-30/40A powered on and transmitting, tweak the front panel POWER ADJUST pot fully clockwise for maximum power out.
  • Page 47 On the SYNTHESIZER tweak the MAX PWR pot (R74) fully counter-clockwise. With the SRPT-30/40A powered on and transmitting, tweak the front panel POWER ADJUST pot fully clockwise. On the SYNTHESIZER tweak the MAX PWR pot (R74) clockwise to the desired maximum output power, but do not exceed Maximum RF Output Power as specified under ORDERING INFORMATION for your model.
  • Page 48 At the maximum specified response frequency, adjust the FREQ RESPONSE tuning slug in coil L1 on COMPRESSOR AUDIO board, 800-166 for maximum level or best response curve. Modulation Adjustment Connect a modulation (or deviation) meter to the output of the SRPT-30/40A. WARNING NEVER CONNECT THE MODULATION METER DIRECTLY TO THE RF OUTPUT CONNECTOR OF THE SRPT-30/40A.
  • Page 49 8/7/2003 Forward Power Calibration – SRPT-40A Only Note: The SRPT-30 Forward Power Calibration can only be performed at the factory. CAUTION THIS ADJUSTMENT HAS BEEN SET AT THE FACTORY AND SHOULD NOT REQUIRE ANY FURTHER ADJUSTMENTS. WARNING TO MAINTAIN CALIBRATION, NEVER ADJUST THE FP CAL (R20) POT ON THE TWO-STAGE RF PA BOARD, OTHERWISE THE FORWARD POWER MUST BE RECALIBRATED.
  • Page 50 8/7/2003 14. Depress and release the front panel EXECUTE pushbutton switch. This command will disable VSWR Foldback. 15. Set the front panel FREQUENCY SELECT pushwheel switches as follows: DECIMAL 7 (far left digit) = “1” DECIMAL 6 = “0” DECIMAL 5 = “4” DECIMAL 4 = “0”...
  • Page 51 8/7/2003 25. Set the front panel FREQUENCY SELECT pushwheel switches as follows: DECIMAL 7 (far left digit) = “1” DECIMAL 6 = “0” DECIMAL 5 = “4” DECIMAL 4 = “0” DECIMAL 3 = “0” DECIMAL 2 = “0” DECIMAL 1 (far right digit) = “0” 26.
  • Page 52 8/7/2003 Reverse Power Calibration - SRPT-40A Only Note: The SRPT-30 Reverse Power Calibration can only be performed at the factory. CAUTION THIS ADJUSTMENT HAS BEEN SET AT THE FACTORY AND SHOULD NOT REQUIRE ANY FURTHER ADJUSTMENTS. WARNING TO MAINTAIN CALIBRATION, NEVER ADJUST THE RP CAL (R17) POT ON THE TWO-STAGE RF PA BOARD, OTHERWISE THE REVERSE POWER MUST BE RECALIBRATED.
  • Page 53 8/7/2003 14. Depress and release the front panel EXECUTE pushbutton switch. This command will disable the front panel POWER ADJUST pot. 15. Set the front panel FREQUENCY SELECT pushwheel switches as follows: DECIMAL 7 (far left digit) = “1” DECIMAL 6 = “2” DECIMAL 5 = “0”...
  • Page 54 8/7/2003 24. Referring to Table (2) - Forward and Reverse Power Calibration, on the TWO-STAGE POWER AMFLIFIER board, tweak the RP CAL pot (R17) counter-clockwise (slowly) until the output power (as indicated by the WATT METER) reaches the REV CAL PWR LEVEL corresponding to your model. WARNING THE RP CAL POT (R17) IS NOW CALIBRATED.
  • Page 55 8/7/2003 44. Adjust the MAX PWR pot (R74) on the SYNHESIZER to the desired maximum output power, but again, do not exceed the Maximum RF Output Power as specified in ORDERING INFORMATION corresponding to your model. 45. Replace the cover on the SYNTHESIZER. 46.
  • Page 56: Drawing 702-122 "Srpt-30/40A Adjustment Locations

    8/7/2003...
  • Page 57: Srpt-30/40A Bill Of Material And Schematics

    8/7/2003 SRPT-30/40A BILL OF MATERIAL SCHEMATICS...
  • Page 58 600-041 40A only SRPT-40A/xxx 705-ST40A-xx 30 only SRPT-30/xxx 705-ST30-xx KIT, BINDER & MANUAL, SRPT-30 979-9967-1 xx(x) = 15(0), 23(0), 25(0), 33(0), yy = 20, 30, 50, or 60 45(0), or 95(0) depending on depending on model frequency band model MAX power...
  • Page 59 SCREW,SEMS 6-32 X 7/16" PAN PH.ST. 422-6107 #6 LOCK SPLIT 423-6002 FILLER,REAR,SRPT-30 471-5385 PANEL,BACK,SRPT-30 471-5386 PANEL,TOP COVER,SRPT-30 471-5387 PANEL,BOTTOM COVER,SRPT-30 471-5388 PARTITION,SRPT-30 471-5389 Screw, 4-40 x 1/4" phillips pan head M/S Nickel Plated 500-004 Screw, 6-32 x 3/8" phillips pan head M/S nickel plated...
  • Page 60 586-115 Ribbon Cable 6" Digi Key #M3AAA1606R-ND 586-134 Cable Assembly, AC Connector to Fuseholder 586-194 Cable Assembly, AC Connector to Ground 586-195 CABLE ASSEMBLY, SRPT-30/40A MN HRNS(SBCM) 586-211 Cover,Two Stage Power Amplifier 700-226-61 Front Panel, SRPT-40A 700-250-42 SRPT-40A Audio Board...
  • Page 61 P/N 705-ST40A-xx SRPT40A/xxx 1/10/03 (see legend below for xx(x) and yy) CABLE, RF OUTPUT, SRPT-40A (SBCM) 949-0365 Cover Gasket 2/4-CH DSTL Drawing #A1D4040 REV 2 DB65112 xx(x) = 15(0), 23(0), 25(0), 33(0), yy = 20, 30, 50, or 60 45(0), or 95(0) depending on depending on model frequency band model MAX power...
  • Page 62 #6 LOCK SPLIT 423-6002 STOFF,ALUM 1/4HEX X 1 1/2 6-32 441-0068 FILLER,REAR,SRPT-30 471-5385 PANEL,BACK,SRPT-30 471-5386 PANEL,TOP COVER,SRPT-30 471-5387 PANEL,BOTTOM COVER,SRPT-30 471-5388 PARTITION,SRPT-30 471-5389 Screw, 4-40 x 1/4" phillips pan head M/S Nickel Plated 500-004 Screw, 6-32 x 3/8" phillips pan head M/S nickel plated...
  • Page 63 800-388Axxx-yy PA ASSY, xxx MHZ, yyW 800-373Axxx-yy Uses one of the following Front Panel Control & Meter Boards: SRPT-30 FP CONTROL & METER BRD ASSY (SBCM) 800-389A SRPT-30 FP CONTROL & METER BRD ASSY (SBCM) 800-382A 14.5 VOLT STEP-UP REGULATOR...
  • Page 64 Kit, Binder-Manual, P/N 979-9967-1 1/10/03 SRPT30/40A REV 1 (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER INSTRUCTION MANUAL, SRPT30/40A REV1 566-035-1 MAN,COVER,MARTI REAR 597-9996 MAN,COVER,MARTI FRONT, W/WINDOW 597-9997 BINDER,MARTI,1 IN,BLUE,W CD POCKET 598-0013 xx(x) = 15(0), 23(0), 25(0), 33(0), yy = 20, 30, 50, or 60 45(0), or 95(0) depending on depending on...
  • Page 65 Cable, RF Output, P/N 949-0365 10/30/02 SRPT-40A (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER Connector, UG-58A/U N panel receptacle Amphenol 8297 550-037 Connector, UG-177/U UHF hood Amphenol 83-765 550-057 CBL,COAX,RG316/U,50 OHM 621-1359 xx(x) = 15(0), 23(0), 25(0), 33(0), yy = 20, 30, 50, or 60 45(0), or 95(0) depending on depending on...
  • Page 66 Cable Assembly, P/N 586-211 10/30/02 SRPT-30/40A Main Harness (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER LUG,QUICK DISCONNECT #18-22 410-1421 LUG,TERM #6 SPADE #16-22 410-1489 HSNG,MOD IV 4 POS 87499-7 AMP 417-0138 CONTACT,CRIMP,MOD-IV 87809-1 417-8766 Solder Lug, #6 Concord 707-1406...
  • Page 67 Cable Assembly, P/N 586-194 10/30/02 AC Connector to (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER Terminal,NICHIFU TMDN #125-250-03FA TERMINAL 512-020 Wire, Stranded UL1015-20/10 Black Tinned Copper 580-130 xx(x) = 15(0), 23(0), 25(0), 33(0), yy = 20, 30, 50, or 60 45(0), or 95(0) depending on depending on model frequency band...
  • Page 68 Cable Assembly, P/N 586-195 10/30/02 AC Connector to Ground (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER Solder Lug, #4 short Concord 707-1204 512-018 Terminal,NICHIFU TMDN #125-250-03FA TERMINAL 512-020 Wire, Stranded UL1015-20/10 Black Tinned Copper 580-130 xx(x) = 15(0), 23(0), 25(0), 33(0), yy = 20, 30, 50, or 60 45(0), or 95(0) depending on depending on...
  • Page 69 14.5 VOLT STEP-UP P/N 800-392A 1/10/03 REGULATOR (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY Open Top Two Circuit Shunt Molex 15-38-1024 550-182 PCB, 14.5 VOLT STEP-UP REGULATOR 800-392B TANTALUM, SMT, D, 100UF, LOW ESR 298-107-1 CAPACITOR, SMT, 1206, 6800 PF, 5% 270-682 Cap., Tantalum, SMT, Size B, 10uF, 16V,Kemet T491B106K016AS...
  • Page 70 RPT-30/SRPT-40 P/N 800-251A 10/30/02 Pre-Amp Mixer (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY Grounding Strap, RPT-30 Pre-Amp 700-250-15 PC Board, Pre-amp/Mixer RPT-30 REV-9520 800-251B Loctite TAK PAK High Temp. Gel #49904 3gm tube 900-018 C1,C2 Cap,monolithic,1000pf 50v 5%KemetC1206C102J5GACTR marked 270-102 C3,C4...
  • Page 71 RPT-30/SRPT-40 P/N 800-251A 10/30/02 Pre-Amp Mixer (see legend below for xx(x) and yy) Potentiometer,25kohm linear taper PC mt Xicon/Alpha #31VQ403 100-143 R31,R32 Resistor, 22.1k ohm 1/4 watt 1% metal film Mepco SFR25 145-223 Resistor, 5.6k ohm 1/4 watt 5% metal film Mepco SFR25 145-562 Switch, side action slide DPDT Ark-Les S-9022CD00-H 530-051...
  • Page 72 P/N 800-166A40A SRPT40A Audio Board 5/2/03 (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY Generic RPU Audio Board Assembly (SBCM) 800-166CM Capacitor, .0024 mfd 2.5% 100v polypro Seacor PFAB240HGUE 215-242 Resistor, 1k ohm 1/4 watt 1% metal film Mepco SFR55 1K 1%TR 145-102 Resistor, 15k ohm 1/4 watt 1% metal film Mepco SFR25 145-153...
  • Page 73 Generic RPU Audio P/N 800-166CM 10/30/02 Board Assembly (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY PC Board, Audio RPT-2/15/30 REV-9526 800-166B Capacitor, 470 pf 50v 10% Y5P disc Jetcon F6Y5P1C471K-JT 253-471 Capacitor, tantalum, 4.7 mf 16v Kemet T350B475K016AS 299-470 Capacitor, 106 50V Radial Electrolytic SPG 515D106M050JA6A 219-106...
  • Page 74 Generic RPU Audio P/N 800-166CM 10/30/02 Board Assembly (see legend below for xx(x) and yy) Resistor, 3.92k ohm 1/4 watt 1% metal film Mepco SFR25 145-392 Resistor, 33.2k ohm 1/4 watt 1% metal film Mepco SFR25 145-333 Resistor, 220 ohm 1/4 watt 1% metal film Mepco SFR25 145-221 Resistor, 2.21 meg ohm 1/4 watt 1% metal film (2.21 Meg 1%) 145-225...
  • Page 75 SRPT40A Front Panel P/N 800-385A 10/30/02 Control & Meter Board (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY PC BOARD, FRONT PANEL CONTROL AND METER, SRPT-40A 800-385B B1,B2 Subminiature Lamp, Lumex IFL-LX2162-16T 510-196 C1,C2 Cap SMT 1mF 16V Tantalum Kemet T491A105M016AS 298-105 Cap,monolithic,1000pf 50v 5%KemetC1206C102J5GACTR marked 270-102...
  • Page 76 SRPT40A Front Panel P/N 800-378A 10/30/02 Control & Meter Board (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY PC Board, Front Panel Control and Meter (NLU-02) 800-378B B1,B2 Subminiature Lamp, Lumex IFL-LX2162-16T 510-196 C1,C2 Cap SMT 1mF 16V Tantalum Kemet T491A105M016AS 298-105 Cap,monolithic,1000pf 50v 5%KemetC1206C102J5GACTR marked 270-102...
  • Page 77 P/N 800-389A 10/30/02 Control & Meter Board (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY SRPT-30 FP CONTROL & METER BRD 800-389B B1,B2 Subminiature Lamp, Lumex IFL-LX2162-16T 510-196 C1,C2 Cap SMT 1mF 16V Tantalum Kemet T491A105M016AS...
  • Page 78 (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY ISOLATOR,ADH BACKED,.063 X .75 400-0055 FLAT .750 X .312 X .030 423-3008 PC BOARD, FP CNTL AND MTR, SRPT-30 800-382B B1,B2 Subminiature Lamp, Lumex IFL-LX2162-16T 510-196 C1,C2 Cap SMT 1mF 16V Tantalum Kemet T491A105M016AS...
  • Page 79 RPU Transmitter P/N 800-379AR 10/30/02 I/O Board Assy (SBCM) (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY Screw, 4-40 x 7/16" phillips pan head MS zinc plated 500-162 PC Board, STL/RPU Transmitter I/O Rev A 800-379B C1-C6 Cap,monolithic,1000pf 50v 5%KemetC1206C102J5GACTR marked 270-102...
  • Page 80 Transmitter Synthesizer P/N 800-375ATxxx 10/30/02 Assembly xxx (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER Transmitter Synthesizer Board Assy Generic (SBCM) 800-375AT RPU/STL XMIT SYN SW VERSION 2 800-375ATSW2 150 MHz Band Model IC, VCO, 135-185 MHz 400-185 230 and 250 MHz Band Models IC, VCO, 215-265 MHz...
  • Page 81 Transmitter Synthesizer P/N 800-375AT 1/10/03 Board Assy (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY TAPE,KAPTON 1/4 700-0119 Exterior Fencing&Cover,Synth Leader Tech88-CBSU-2.25x5.75x.8 700-226-63 PC Board, Transmitter Synthesizer, 800-375B Cap.,Tantalum,SMT, Size D, 100uF, 16V,Kemet T491X107K016AS 298-107 Cap.,Tantalum,SMT, Size D, 100uF, 16V,Kemet T491X107K016AS 298-107 Capacitor,Tantalum,SMT,size D, 47uF,16V Kemet T491D476K016AS 298-476...
  • Page 82 Transmitter Synthesizer P/N 800-375AT 1/10/03 Board Assy (see legend below for xx(x) and yy) C57,C58 Capacitor,monolithic chip,33 pf 50v 5% Kemet C1206C330J5GAC 270-330 C59,C60 Cap.,Tantalum,SMT, Size D, 100uF, 16V,Kemet T491X107K016AS 298-107 Cap,monolithic,1000pf 50v 5%KemetC1206C102J5GACTR marked 270-102 Cap SMT 1mF 16V Tantalum Kemet T491A105M016AS 298-105 Diode, Zener, SMT, 13V, Vishay BZX84C13TR 415-840...
  • Page 83 Transmitter Synthesizer P/N 800-375AT 1/10/03 Board Assy (see legend below for xx(x) and yy) Resistor, 1K ohm 1/8 watt 1% chip Dale CRCW1206-1K 185-102 R46-R49 Resistor, SMT, size 1206, 47.5K ohms, Dale CRCW1206-47.5K 185-47.5K R50,R51 RESISTOR, SMT, 1206, 1.82K, 1% 185-1.82K Resistor, 10K ohm 1/8 watt 1% chip Dale CRCW1206-10K 185-103...
  • Page 84 PA ASSY, P/N 800-388Axxx-yy 1/10/03 or 800-373Axxx-yy xxx MHZ, yyW (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY SCREW,SEMS 6-32 X 7/16" PAN PH.ST. 422-6107 #4 FLAT SS .250 X .125 X .018 423-4001 Screw, 4-40 x 1/2" phillips pan head M/S nickel plated 500-011 Lockwasher, #4 internal tooth small pattern zinc plated 500-055...
  • Page 85 PA ASSY, P/N 800-388Axxx-yy 1/10/03 or 800-373Axxx-yy xxx MHZ, yyW (see legend below for xx(x) and yy) IC, PA MODULE, 215-250 MHZ, 30W 468-729 250 MHz Band, 30W Model C35-C37 Capacitor, SMT, 10 pF, 100V 270-100-1 D1,D2 Not Used Inductor, SMT, 1812, 33 nH 350-203 L9,L10 Inductor, SMT, 1812, 47 nH...
  • Page 86 PA ASSY, P/N 800-388Axxx-yy 1/10/03 or 800-373Axxx-yy xxx MHZ, yyW (see legend below for xx(x) and yy) L9,L10 Inductor, SMT, 1206, 8 nH 350-199 Inductor, SMT, 1206, 5 nH 350-198 Resistor, SMT, 2512, 51 ohm, 1 Watt 184-510 Resistor, SMT, 1206, 22.1K 185-22.1k IC, PA MODULE, 935-965 MHZ, 20W 467-760...
  • Page 87 TWO-STAGE RF PA P/N 800-388A 1/10/03 or 800-373A BOARD ASSEMBLY (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY TAPE,KAPTON 1/4 700-0119 RF Shielding Fence For Power Amplifier(Interior) 700-226-59 Leader Tech Fence # 47-CBSU-2.75 X 5.75 X .4 NO COVER 700-268 PC BOARD, TWO-STAGE RF PA 800-388B...
  • Page 88 TWO-STAGE RF PA P/N 800-388A 1/10/03 or 800-373A BOARD ASSEMBLY (see legend below for xx(x) and yy) Resistor, 10K ohm 1/8 watt 1% chip Dale CRCW1206-10K 185-103 Resistor, 1K ohm 1/8 watt 1% chip Dale CRCW1206-1K 185-102 Resistor, SMT, size 1206, 47.5K ohms, Dale CRCW1206-15K 185-47.5K Resistor, 1K ohm 1/8 watt 1% chip Dale CRCW1206-1K 185-102...
  • Page 89 P/N 959-0321 ASSY., THERMOCOUPLE 10/30/02 (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER Thermistor, Fenwal 142-102-FAG-RB1 1000 OHM @ 25C 10% 120-002 Terminal, vinyl insulated C10 #10 stud #10-12 wire 512-002 Hysol Epoxi-Patch Kit 11C Black 900-019 xx(x) = 15(0), 23(0), 25(0), 33(0), yy = 20, 30, 50, or 60 45(0), or 95(0) depending on...
  • Page 90 600-041 40A only SRPT-40A/450 TSL 705-ST40AT-4 30 only SRPT-30/450 TSL 705-ST30T-4 KIT, BINDER & MANUAL, SRPT-30 979-9967-1 xx(x) = 15(0), 23(0), 25(0), 33(0), yy = 20, 30, 50, or 60 45(0), or 95(0) depending on depending on model frequency band...
  • Page 91 SCREW,SEMS 6-32 X 7/16" PAN PH.ST. 422-6107 #6 LOCK SPLIT 423-6002 FILLER,REAR,SRPT-30 471-5385 PANEL,BACK,SRPT-30 471-5386 PANEL,TOP COVER,SRPT-30 471-5387 PANEL,BOTTOM COVER,SRPT-30 471-5388 PARTITION,SRPT-30 471-5389 Screw, 4-40 x 1/4" phillips pan head M/S Nickel Plated 500-004 Screw, 6-32 x 3/8" phillips pan head M/S nickel plated...
  • Page 92 Ribbon Cable 6" Digi Key #M3AAA1606R-ND 586-134 Cable Assembly, AC Connector to Fuseholder 586-194 Cable Assembly, AC Connector to Ground 586-195 CABLE ASSEMBLY, SRPT-30/40A MN HRNS(SBCM) 586-211 Cover,Two Stage Power Amplifier 700-226-61 Front Panel, SRPT-40A 700-250-42 SRPT30/40A TSL Audio Board...
  • Page 93 P/N 705-ST40AT-4 SRPT40A/450 TSL 5/2/03 (see legend below for xx(x) and yy) CABLE, RF OUTPUT, SRPT-40A (SBCM) 949-0365 Cover Gasket 2/4-CH DSTL Drawing #A1D4040 REV 2 DB65112 xx(x) = 15(0), 23(0), 25(0), 33(0), yy = 20, 30, 50, or 60 45(0), or 95(0) depending on depending on model frequency band...
  • Page 94 #6 LOCK SPLIT 423-6002 STOFF,ALUM 1/4HEX X 1 1/2 6-32 441-0068 FILLER,REAR,SRPT-30 471-5385 PANEL,BACK,SRPT-30 471-5386 PANEL,TOP COVER,SRPT-30 471-5387 PANEL,BOTTOM COVER,SRPT-30 471-5388 PARTITION,SRPT-30 471-5389 Screw, 4-40 x 1/4" phillips pan head M/S Nickel Plated 500-004 Screw, 6-32 x 3/8" phillips pan head M/S nickel plated...
  • Page 95 800-388Axxx-yy PA ASSY, xxx MHZ, yyW 800-373Axxx-yy Uses one of the following Front Panel Control & Meter Boards: SRPT-30 FP CONTROL & METER BRD ASSY (SBCM) 800-389A SRPT-30 FP CONTROL & METER BRD ASSY (SBCM) 800-382A 14.5 VOLT STEP-UP REGULATOR...
  • Page 96 P/N 800-166A40ATSL SRPT30/40A TSL Audio Board 5/2/03 (see legend below for xx(x) and yy) SYMBOL DESCRIPTION PART NUMBER QTY RIV,CLOSED-END .125 X .316L 421-1113 Generic RPU Audio Board Assembly (SBCM) 800-166CM Capacitor, .022 mfd 2.5% 100v polypro Seacor 215-223 Resistor, 1k ohm 1/4 watt 1% metal film Mepco SFR55 1K 1%TR 145-102 Resistor, 8.25k ohm 1/4 watt 1% metal film 145-822...