In order to prolong the service life and performance of your searchlight, the following
maintenance guidelines are recommended:
◼ Maintenance checks should be conducted before every voyage or at least every three
months;
◼ Before checking, disconnect the equipment from the supply;
◼ Visually inspect the condition of the equipment;
◼ Any major or minor structural damage should be rectified immediately in order to reduce
sympathetic wear;
◼ After inspection it may be necessary to clean the inside of the searchlight. The following
procedure should be adhered to:
◼ Remove the upper casting by removing the five M8 socket bolts with the dubo washer on
the underneath of the searchlight,
◼ Clean the front glass inside and out using a proprietary glass cleaner;
◼ Clean the reflector if required;
◼ Check earth point for conductivity;
◼ It is advisable to check all seals and gaskets for signs of degradation. Renew if necessary;
◼ The searchlight is fitted with a breather unit. This ensures a steady airflow in order to pre-
vent any vacuum forming within the barrel.
◼ Upon completing all maintenance requirements, the searchlight should be tested for full
working order (approximately 20 minutes).
If in any doubt as to the correct servicing procedures to adopt, please contact your dis-
tributor/agent or the manufacturer who will be able to advise the best course of action
for your product.