Francis Searchlights Voyager 2 User Instruction & Installation Manual page 24

A7185 vx500 150w 24v xenon
Table of Contents

Advertisement

1. Pan Limit. – Either of the pan limit switches operated. Note that this
may not actually be a fault. The LED will flash when a limit switch is
operated under normal circumstances i.e. the lamp is at the limit of
travel.
2. Tilt Limit. – Either of the tilt limit switches operated. Note that this may
not actually be a fault. The LED will flash when a limit switch is operat-
ed under normal circumstances i.e. the lamp is at the limit of travel.
3. Pan motor over current. – The pan motor is taking excessive current.
The motor will be disabled for a period when this occurs. Fault indica-
tion will remain until power is removed.
4. Tilt motor over current. – The tilt motor is taking excessive current. The
motor will be disabled for a period when this occurs. Fault indication
will remain until power is removed.
5. Focus motor over current. – The focus motor is taking excessive cur-
rent. The motor will be disabled for a period when this occurs. Fault in-
dication will remain until power is removed.
6. FBUS interface over current. – The speed control card supplies 24VDC
to the remote-control panels. This fault indicates the 24VDC output is
taking excessive current. The FBUS supply output will switch off. To
restore this output, remove the supply from the speed control card for a
period.
7. Anti-condensation heater output over current. – The 24VDC anti con-
densation heater output is taking excessive current. The heater output
will switch off. To restore this output, remove the supply from the speed
control card for a period.
8. Limit Switch Error. Some lamp types do not use all or some limit
switches. If an invalid limit switch input is detected it is probable the
speed control card is set to the wrong product or there is a wiring error.
9. Datum Error. The start-up datum system has not completed correctly.
10. Product type not set or corrupt. The product type has not been set, has
been set incorrectly or is corrupt.
11. Supply voltage out of tolerance. The 24V supply is outside the range
18-30V.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vx500A7187 vx500 100w 230v xenon

Table of Contents