V5 series inverter
P9.00
P9.00
P9.00
P9.00
Traverse
Traverse
Traverse
Traverse operation
0 0 0 0 :Disabled
Disabled
Disabled
Disabled
1 1 1 1 :Enabled
Enabled
Enabled
Enabled
P9.01
Traverse
P9.01
P9.01
P9.01
Traverse
Traverse
Traverse operation
Unit' ' ' ' s s s s place
Unit
Unit
place
place
place of of of of LED
LED
LED
LED:start mode
Unit
0 0 0 0 :Auto
Auto mode
Auto
Auto
mode
mode
mode. . . . The inverter will running at preset frequency (P9.02) for certain time (P9.03), and then enter the traverse
operation.
1 1 1 1 :Manual
Manual
Manual
Manual mode
mode
mode. . . . If the multi-function terminal (Xi is set to No.25 function) is enabled, the inverter will enter traverse
mode
mode. If the terminal is disabled, the drive will end traverse operation and operate at the pre-traverse frequency (P9.02).
Ten
Ten
Ten
Ten' ' ' ' s s s s place
place
place of of of of LED
place
LED:Traverse operating amplitude
LED
LED
0 0 0 0 :Variable
Variable
Variable
amplitude
amplitude. . . . Traverse operating amplitude AW changes with the central frequency and the change rate is defined
amplitude
Variable amplitude
by P9.04.
1 1 1 1 :Fixed
Fixed
Fixed
amplitude
amplitude . . . . Traverse operating amplitude AW is decided by max frequency and P9.04.
amplitude
Fixed amplitude
P9.02
Pre-traverse
P9.02
P9.02
P9.02
Pre-traverse
Pre-traverse frequency
Pre-traverse
P9.03
Waiting
time
P9.03
P9.03
P9.03
Waiting
Waiting
Waiting time
time before
time
P9.02 is used to set running frequency before inverter enter traverse state.
If you select auto start mode, P9.03 is used to set the holding time with pre-traverse frequency before the inverter enter
traverse state; if you select manual start mode,P9.03 is disabled. Refer to Fig. 4-45 for introduction.
P9.04
P9.04
P9.04
P9.04
Traverse operating amplitude
Variable amplitude:Aw=Central frequency×P9.04
Fixed amplitude:Aw=Max operting frequency P0.06×P9.04
Prompt:The traverse frequency will be limit by upper/lower limit of frequency, and the traverse operation will not work
abnormally with unsuitable setup.
P9.05
P9.05
P9.05
P9.05
As shown in Fig4-45, there is no jitter frequency if P9.05 is set to 0.
P9.06
P9.06
P9.06
P9.06
Traverse operating
Traverse
Traverse
Traverse
It defines the time of a complete traverse operation cycle including rising and falling processes.
P9.07
P9.07
Rising time of trangle wave
P9.07
P9.07
Running time of traverse rising stage=P9.06×P9.07(s),Time of falling stage=P9.06×(1-P9.07)(s)。Refer Fig.4-45
for introduction
Note:You can select S-curve Acc/Dec mode along with traverse so as to make the traverse operating more smoothly.
Note
Note
Note
P9.08
P9.08
Reference
Reference
length
length
P9.08
P9.08
Reference
Reference length
length
P9.09
P9.09
Actual
Actual
length
length
P9.09
P9.09
Actual
Actual length
length
P9.10
P9.10
P9.10
P9.10
Times
Times
Times
Times of of of of length
length
length
length
correction
correction
coefficient
coefficient of of of of
coefficient
correction
correction coefficient
P9.11
P9.11
P9.11
P9.11
length
length
length
length
P9.12
P9.12
Perimeter
Perimeter
Perimeter of of of of shaft
P9.12
P9.12
Perimeter
P9.13
P9.13
Number of of of of pulses
Number
Number
pulses
pulses
P9.13
P9.13
Number
pulses per
This group of parameters are used for fixed length control.
The drive inputs counting pulses via terminals (X6, defined as function 35), and calculate length according to the number of
pulses per revolution (P9.13) and perimeter of shaft (P9.12).
Calculated length=Number of pulses÷number of pulses per revolution×perimeter of shaft
86
operation
operation selection
operation
selection
selection
selection
operation
control
mode
operation control
operation
control mode
control
mode
mode
frequency
frequency
frequency
before
pre-traverse
frequency
before
before pre-traverse
pre-traverse
pre-traverse frequency
frequency
frequency
Jitter
Jitter
Jitter
Jitter frequency
frequency
frequency
frequency
operating
operating cycle
operating
cycle
cycle
cycle
shaft
shaft
shaft
per
per
revolution
revolution
per revolution
revolution
Range
Range:0 0 0 0 , , , , 1 1 1 1
Range
Range
Range
Range
Range
Range:00 00 00 00~11 11 11 11
Range
0.00
650.00Hz
Range
Range
Range:0.00
0.00-650.00Hz
0.00
650.00Hz
650.00Hz
Range
Range
Range:0.0
Range
0.0
0.0
0.0-6000.0s
6000.0s
6000.0s
6000.0s
Range
Range
Range:0.0
Range
0.0~50.0
0.0
0.0
Range
Range
Range:0.0
Range
0.0
0.0
0.0~50.0
Range
Range
Range
Range:0.1
0.1~999.9s
0.1
0.1
Range
Range
0.0
0.0
Range
Range:0.0
0.0~98.0
Range
Range
0.000
0.000
65.535km
65.535km
Range:0.000
Range
0.000~65.535km
65.535km
Range
0.000
65.535km
Range
Range:0.000
Range
0.000
0.000~65.535km
65.535km
65.535km
Range
Range
Range
Range:0.001
0.001
0.001~30.000
0.001
30.000
30.000
30.000
Range
Range
0.001
0.001
1.000
1.000
Range
Range:0.001
0.001~1.000
1.000
Range
Range
0.01
0.01
100.00(cm)
100.00(cm)
Range:0.01
Range
0.01~100.00(cm)
100.00(cm)
Range:1 1 1 1 ~9999
Range
Range
9999
9999
Range
9999
50.0
50.0
50.0%
50.0
50.0
50.0%
999.9s
999.9s
999.9s
98.0
98.0
98.0%
0.000(km)
0.000(km)
0.000(km)
0.000(km)
0.000(km)
0.000(km)
0.000(km)
0.000(km)
10.00(cm)
10.00(cm)
10.00(cm)
10.00(cm)
0 0 0 0
0 0 0 0
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.0s
0.0s
0.0s
0.0s
0.0
0.0
0.0
0.0%
0.0
0.0
0.0
0.0%
10.0s
10.0s
10.0s
10.0s
50.0
50.0
50.0
50.0%
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1 1 1 1