P3.01
Parameter initialization
locking up
P3.02
Parameter copy
P3.03
Auto
function
P3.04
AVR function
P3.05
Gain
compensation
P3.06
Jog operating frequency
P3.07
Acc time of jog operation
P3.08
Dec time of jog operation
P3.09
Communication
config
P3.10
Local address
P3.11
Delay for responding to c
Unit's place:
0: All parameters are allowed
modifying
1: Only P3.01 can be modified
2:Only P0.02 and P3.01 can be
modified
Ten's place:
0:disabled
1:Restore to factory setting
2:Clear fault record
0:disabled
1:parameter upload
2:parameter download
Note:Function is still in developing
energy-saving
0:disabled
1:Enabled
0:disabled
1:enable all the time
2: Disabled in Dec process
of
slip
0~150%
0.10~50.00Hz
0.1~60.0s
0.1~60.0s
LED unit's place:baud rate selection
0:1200BPS
1:2400BPS
2:4800BPS
3:9600BPS
4:19200BPS
5:38400BPS
LED ten's place:data format
0:1-7-2 foramt,no parity check
1:1-7-1 format,Odd
2:1-7-1 format,Even
3:1-8-2 format,None
4:1-8-1 format,Odd
5:1-8-1 format,Even
6:1-8-1 format,None
(When
communication mode ,please select
data mode 3~6。)
LED hundred's place:
undefined
0~248
0:broadcast address
248:inverter as the host address
0.0~1000.0s
1
1
1
1
1
use
Modbus-RTU
1
V5 series inverter
00
0
0
0
1%
0%
0.01Hz
5.00Hz
0.1s
5.0s
0.1s
5.0s
054
1
0.1s
0.0s
×
×
×
×
×
×
×
×
41