TABLE 17 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,600 CFM (B1HA048)
OUTDOOR
TEMPERATURE,
°F
55
65
11.4
70
10.3
75
9.3
80
8.2
85
7.2
90
6.5
95
5.9
100
-
105
-
110
-
115
-
TABLE 18 -
HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,600 CFM (B1HA048)
INDOOR DB
TEMPERATURE,
°F
-10
55
8.3
70
-
80
-
TABLE 19 -
COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 2,000 CFM (B1HA060)
OUTDOOR
TEMPERATURE,
°F
55
65
26.7
70
21.9
75
17.0
80
12.2
85
7.3
90
7.2
95
7.0
100
7.2
105
7.4
110
7.6
115
7.8
TABLE 20 -
HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 2,000 CFM (B1HA060)
INDOOR DB
TEMPERATURE,
°F
-10
55
5.5
70
-
80
-
Unitary Products Group
INDOOR WB TEMPERATURE, °F
57
59
61
12.4
13.5
14.6
11.2
12.2
13.1
10.0
10.8
11.6
8.8
9.4
10.0
7.7
8.1
8.5
7.0
7.4
7.9
6.3
6.8
7.2
5.5
6.1
6.6
-
5.4
6.1
-
-
5.5
-
-
-
HEATING SUPERHEAT AT COMPRESSOR SUCTION, °F
0
10
8.4
8.6
-
-
-
-
INDOOR WB TEMPERATURE, °F
57
59
61
27.6
28.5
29.4
23.0
24.1
25.2
18.3
19.7
21.0
13.7
15.3
16.8
9.1
10.8
12.6
8.3
9.4
10.6
7.5
8.0
8.5
7.6
8.0
8.3
7.7
7.9
8.2
7.8
7.9
8.1
7.8
7.9
7.9
0
10
5.7
6.2
-
-
-
-
63
65
67
15.7
16.8
17.9
14.0
14.9
15.9
12.3
13.1
13.9
10.6
11.2
11.8
9.0
9.4
9.8
8.3
8.8
9.2
7.7
8.1
8.6
7.2
7.8
8.4
6.8
7.5
8.2
6.3
7.2
8.0
5.9
6.9
7.8
20
30
9.0
10.1
-
-
-
-
63
65
67
30.3
31.2
32.1
26.3
27.4
28.5
22.3
23.7
25.0
18.4
19.9
21.5
14.4
16.2
17.9
11.7
12.8
13.9
9.0
9.5
9.9
8.7
9.1
9.5
8.5
8.7
9.0
8.2
8.4
8.5
8.0
8.0
8.1
OUTDOOR TEMPERATURE, °F
20
30
6.8
8.0
-
-
-
-
035-16004-001-A-0202
69
71
73
19.3
20.7
22.1
17.4
18.9
20.4
15.4
17.0
18.6
13.5
15.2
16.9
11.6
13.4
15.1
10.6
12.0
13.4
9.6
10.6
11.6
9.3
10.3
11.3
9.1
10.1
11.0
8.9
9.8
10.7
8.7
9.5
10.4
40
50
12.4
17.4
4.2
9.2
-
5.7
69
71
73
33.0
33.9
34.8
30.0
31.4
32.8
27.0
28.9
30.9
24.0
26.5
29.0
20.9
24.0
27.0
17.3
20.6
23.9
13.6
17.2
20.8
12.4
15.3
18.2
11.2
13.4
15.6
10.0
11.5
13.0
8.8
9.6
10.3
40
50
9.9
13.1
4.8
8.0
-
5.6
75
23.5
21.9
20.2
18.5
16.9
14.8
12.6
12.3
11.9
11.6
11.2
60
28.6
20.4
16.9
75
35.7
34.3
32.9
31.4
30.0
27.2
24.4
21.1
17.8
14.4
11.1
60
18.6
13.4
11.0
13