Physical And Electrical Data - York TCHE24 Technical Manual

Horizontal discharge split system air conditioners 14 seer – r-410a – 1 phase, 2, 3, 4 nominal tons
Hide thumbs Also See for TCHE24:
Table of Contents

Advertisement

PHYSICAL AND ELECTRICAL DATA

MODEL
Unit Supply Voltage
1
Normal Voltage Range
Minimum Circuit Ampacity
Max. Overcurrent Device Amps
Min. Overcurrent Device Amps
Type
Compressor Amps
Rated Load
Locked Rotor
Crankcase Heater
Factory External Discharge Muffler
Factory External Check Valve
4
HS Kit Required with TXV
Fan Diameter Inches
Rated HP
Rated Load Amps
Fan Motor
Nominal RPM
Nominal CFM
Face Area Sq. Ft.
Coil
Rows Deep
Fins / Inch
Max. Length
5
Max. Lift
Refrigerant Lines
Max. Drop
Liquid Line Set OD (Field Installed)
Vapor Line Set OD (Field Installed)
6
Unit Charge (Lbs. - Oz.)
Charge Per Foot, Oz.
Operating Weight Lbs.
1. Rated in accordance with AHRI Standard 110-2012, utilization range "A".
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. When more than 50 feet of interconnecting tubing and more than 30 feet of vertical lift is used, consult the Application Data (part number 247077). For long-line
applications, interconnecting lines over 100 feet must be installed with liquid line solenoid.
6. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or sub-
tract the amount of refrigerant, using the difference in length multiplied by the per foot value.
A
Johnson Controls Unitary Products
2
3
C
B
TCHE24S41S1
208-230V, 1 60Hz
18.3
30
20
Scroll
13.5
58.3
Yes
No
No
No
23
1/4
1.3
850
3200
11.96
1
23
200
65
150
3/8
3/4
5 - 0
0.62
195
DIMENSIONS
Unit
Model
TCHE24S41S1
TCHE36S41S1
TCHE48S41S1
.
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of mounting feet to top of unit.
Overall length and width include mounting feet and screw heads.
5371951-YTG-A-0517
TCHE36S41S1
187 to 252
19.1
30
20
Scroll
14.1
72.2
Yes
No
No
No
23
1/4
1.3
850
3200
11.96
1
23
200
65
150
3/8
3/4
6 - 6
0.62
215
Dimensions
Refrigerant Connection
(Inches)
A
B
C
37-1/4
20
45
37-1/4
20
45
43-1/4
20
45
TCHE48S41S1
24.6
40
25
Scroll
18.5
124.0
Yes
No
No
No
23
1/4
1.3
850
3050
13.96
1
23
200
65
150
3/8
7/8
7 - 4
0.67
240
Service Valve Size
Liquid
Vapor
3/4
3/8
7/8
3