1) Grade[Class A]: The module is a 'Class A' grade.
[Class A: This grade is regarded as a device operated above
50V or above 240W and a product where an ordinary person's approach is expected.
It acquired the safety standard under IEC 61730-1 and IEC 61730-2]
2) Installation site: The module should be installed at a place satisfying the following
Respect.
※ Safety load
A 60 series product was designed to tolerate the wind load(the back side)
of 2400Pa, snow load(the front side) of 5400pa, and a 72 series product was
designed to tolerate the wind load(the back side) of 2400pa, snow load(the
front side) of 5400pa.
When the maximum snowfall and wind load on the site are above the standard,
a structure to install the module on should be designed to satisfy the mechanical
load of the site.
※ Operating temperature
A ambient temperature of module installation site is limited by the
minimum and maximum temperature as shown below.
* Maximum operating temperature: +85℃[Under the hot temperature,
ventilation should be considered.]
* Minimum operating temperature: -40℃
[Considerations when temperature rises: output is reduced due to
characteristics of the module]
※ Places where the installation is prohibited
A site directly contacting salt injury
A site having poor drainage [Poor drainage can shorten the module life ]
A site having a shade caused by the geographic features of the surrounding area.
A site where stones and foreign matters are often thrown near to the modules.
[There are concerns for damage to the front window of the module.)
POSITION
60SERIES
A
290
B
460
C
990
D
1650
E
942.5
F
1425.9
G
30
72SERIES
345
550
990
1970
942.5
1589.6
40