8. Grounding Method

For preventing electric shock and fire, the frame of PV module shall be
grounded properly. [Please be sure to remove a coated portion when grounding,
because the PV module aluminum frame is coated with anodizing.]
[Before installation]
Configuration
Size and material
A
M4 Bolt
B
M4 Star washer
C
M4 Plat washer
D
M4 Cup washer
E
Grounding wire
F
M4 Plat washer
G
M4 Nut
Materials
*SUS304: Bolt, Nut, Washer (Steel Use Stainless)
*Grounding wire: Copper
Torque: 0.9Nm ~ 1.1Nm
For the detail of Earth, refer to NEC(National Electric Code) 690 grounding PV
arrays for special requirements.
9. Detailed module specification
① Electrical Specifications
■ 60cells
STC
[After installation]
■ 72cells
STC
remarks
16mm
12AWG
③ Temperature Characteristics
(Irradiance 1000W/m2 ,Module temperature 25℃, AP-1.5)
Rated power(Pmax)
Voltage at Pmax(Vmp)
Current at Pmax(Imp)
Warranted minimum Pmax
Short-Circuit Current (Isc)
Open-Circuit Voltage (Voc)
Module Effeciency
Operating module temperature
Maximum System Voltage
Maximum Series Fuse Rating
Maximum Reverse Current
Measurement tolerance
(Irradiance 1000W/m2 ,Module temperature 25℃, AP-1.5)
Rated power(Pmax)
Voltage at Pmax(Vmp)
Current at Pmax(Imp)
Warranted minimum Pmax
Short-Circuit Current (Isc)
Open-Circuit Voltage (Voc)
Module Effeciency
Operating module temperature
Maximum System Voltage
Maximum Series Fuse Rating
Maximum Reverse Current
Measurement tolerance
Item
Temperature coefficient of Isc
Temperature coefficient of Voc
Temperature coefficient of power
NOCT
(Air 20 ; Sun 0.8kW/m2 ; Wind 1m/s)
SN245P-10 SN250P-10 SN255P-10
245 W
250 W
255 W
29.2 V
29.7 V
30.0 V
8.39 A
8.42 A
8.50 A
245 W
250 W
255 W
8.85 A
8.86 A
8.93 A
37.3 V
37.3 V
37.6 V
15.00%
15.30%
15.61%
-40℃ to +85℃
1000VDC (IEC)
15A
20.25A
2.5%
±
SN300P-10 SN305P-10 SN310P-10
300 W
305 W
310 W
35.6 V
36.0 V
36.3 V
8.44 A
8.47 A
8.54 A
300 W
305 W
310 W
8.88 A
8.90 A
8.96 A
44.9 V
45.1 V
45.4 V
15.38%
15.64%
15.89%
-40℃ to +85℃
1000VDC (IEC)
15A
20.25A
±2.5%
Value
0.052%/℃
-0.312%/℃
-0.429%/℃
45±3℃