Please observe the following instructions:
Quality of wood pellets:
Depending on the manufacturer there are light, dark, shorter and longer pellets. And the quality of one delivery may
differ from another even from the same supplier. The standards for wood pellets are becoming more and more strict
but wood is wood and has its own characteristics regarding ash and clinker.
Cleaning requirements:
As soon as you find ash and clinker deposits in the cold combustion pot, it must be cleaned. See operating
instructions! If this is not done, there will be more and more clinker. Then the device will no longer be able to ignite
properly. Pellets may pile up in the combustion pot. In extreme cases, this can reach all the way back to the pellet
chute. Backfire in the pellet container and smouldering in the pellet tank might possibly result. This will destroy
your device and is not covered by the guarantee.
For maximum working life:
Arrange for commissioning by your trained stove supplier.
Observe the daily check as described and more frequently if you have received new pellet deliveries or when
the device is brought back into use after the summer.
Carefully read through all the operating instructions and retain them.
Type number:
Installation and operating instructions
Important manufacturer's instructions
Art. no. 05713070001400
V14 E15
Pellett Stove
HSP 2.17
!

Advertisement

Table of Contents
loading

Summary of Contents for HAAS + SOHN HSP 2.17

  • Page 1 Art. no. 05713070001400 V14 E15 Pellett Stove HSP 2.17 Installation and operating instructions Important manufacturer’s instructions Please observe the following instructions: Quality of wood pellets: Depending on the manufacturer there are light, dark, shorter and longer pellets. And the quality of one delivery may differ from another even from the same supplier.
  • Page 2: Table Of Contents

    Index of contents 9.6..1 Backlighting 9.6..2 Activating the backlighting Description 9.7. Induced draught fan with rotation speed feedback 18 General instructions, safety instructions 9.8. Flame or combustion chamber temperature sensor (combustion chamber thermosensor) Installation of the pellet stove and connection to the chimney 9.9.
  • Page 3: Description

    Congratulations! You are the owner of a HAAS + SOHN pellet stove, a quality product. Please read through 2. General instructions, safety instructions these instructions carefully. They will tell you all about  Before commissioning the pellet stove read the...
  • Page 4: Installation Of The Pellet Stove And Connection To

    3. Installation of the pellet stove and connection to  the chimney The pellet stove may not be installed in the open air! The packaging on your new pellet stove gives it optimum protection against damage. Nevertheless, damage may  Attention! The mains cable plug must remain freely have occurred to the stove or to accessories in transit.
  • Page 5 Floor protection The floor is to be protected from the radiant heat from Since excess pressure may build up at the smoke outlet the area of the viewing window (combustion chamber). because of the way that the pellet stove works with an In addition, for practical reasons associated with induced draught fan, all fume outlet pipes as far as the cleaning it is recommended that you install your pellet...
  • Page 6: The Pellet Stove's Functional Characteristics

    5. The pellet stove’s operating statuses: The operation of the pellet stove is characterised by 8 operating statuses: The ignition phase begins the current room temperature falls below the set target temperature by 1ºC and the stove has cooled down to a temperature of below 70C°.
  • Page 7: Burner Test / Cleaning

    shutdown will be initiated and an error message is Attention! shown on the operator console display. The device starts by itself in “Standby mode”. During the “Heating mode” operating status, the Because of the heat generated on the panel, you maximum and minimum heat output are each controlled must ensure that there is no-one who is unfamiliar by safety limits (maximum and minimum flue gas...
  • Page 8: Switching Off - Operating Status Off

    6.2. Description of the symbols Switching off – operating status OFF 5.8. Procedure: Press the left key. OFF mode is displayed in icon on the display.The stove Time initiates the Cooling down operating status and can no longer switch to Heating mode by itself, even if the room Room temperature-target temperature falls below the set room temperature.
  • Page 9: Standard Screen /Welcome Page

    6.3. Standard screen /welcome page 6.3..3 Setting target room temperature This page will always be displayed when the power plug Procedure: is connected to the power outlet. By pressing the middle button you adjust the room temperature. By pressing 16:18 ✔...
  • Page 10: Setting The Date And Time

    6.4..1 Setting the date and time Desription – Heating profile 6.4..3 Date/time Heating profile h003 Heating profile Fr, 13.09.2013 Setting range 14:39:28 ( 2 ) O.K. Procedure: Setting range from 1 to 4 ✔ Set the Courser on "Date/Time" and press OK Factory setting: 2 The value to be set depends on the size of the room that is to be heated.
  • Page 11: Desription - Display Brightness - Contrast Setting

    Procedure: ✔ Press "Quit" with the right button and the error Set the cursor to the "ECO mode" in the main menu. can be confirmed. Press the right "OK" push-button. Look point 11 on page 22 Change the setting with the use of both middle push- buttons.
  • Page 12: Commissioning Your Pellet Stove

    A simple quality test: Put a few wood pellets in a glass of Tip!! Only when commissioning, place about 30 water: Good quality: Pellets sink pellets in the burner. This will speed up the Lower quality: Pellets float. ignition process. General: The use of lower-quality or unauthorised fuel adversely If the ignition phase could not be successfully...
  • Page 13: Cleaning The Surface

    8.4. Cleaning the combustion pot -weekly During operation, deposits may form in the combustion 8.1. Cleaning the surface pot. How quickly the combustion pot becomes dirty depends solely on fuel quality. The deposits or Dirt on the upper surface of the stove may be cleaned off with a damp cloth or if necessary with mild soapy encrustations must be removed from time to time water.
  • Page 14: Cleaning The Pellet Container - Annual Maintenance

    8.5. Cleaning the pellet container - annual 8.6. Cleaning the flue gas passes - annual maintenance maintenance First pull the stove away from the wall so as to create enough room to work at the back. Heat the pellet stove until the storage tank is completely To clean the flue gas passes, proceed as follows: empty.
  • Page 15 Figure 8b: Tilt out the front part...
  • Page 16: Cleaning The Induced Draught Housing And Fan

    Undo the screws and remove both the covers of the 9. Description of the components openings. Tilt out the front part (see Fig. 8b, detail 3A) 9.1. Storage container (pellet tank) 17 kg of wood pellets can be stored in the storage After completion of the cleaning make sure that container.
  • Page 17: Combustion Pot With Tray

    9.3. Combustion pot with tray: The combustion pot is made of high-grade cast iron. The special design of the combustion pot guarantees clean and extremely efficient combustion of the wood pellets. Figure 13: Stainless steel ignition 9.5. Control unit Figure 11: Combustion pot correctly installed microprocessor control unit...
  • Page 18: Operator Console

    9.6. Operator console the air volume required for the combustion of the energy level located in the grate. Here the ACTUAL flame temperature is compared with the TARGET in combination with the processor- regulated control unit and the appropriate combustion air volume required for the combustion of the energy level in the grate is supplied by means of the induced draught fan.
  • Page 19: Oc - Overheat Cutout

    9.11. OC – Overheat cutout 9.13. Flue tube connection The overheat cutout sensor is located on the The diameter of the flue elbow is 80 mm. The flue screw conveyor tube. When a certain temperature tube must be connected to the fireplace in is reached, the OC is triggered independently of the accordance with official regulations.
  • Page 20: Technical Data

    400 W Electric ignition (for max. 15 minutes on ignition): Electronics fuses: (F3) T 0.315 A, 250 V Fuses for the ignition, screw conveyor motor, induced T 3,15 A, 250 V draught, (F1,) (F2 reserve) Figure 19: Dimensions of HSP 2.17...
  • Page 21: Faults, Causes, Correction

    11. Faults, causes, correction You can correct simple faults yourself with the following guide. For further information please consult your specialist dealer. Attention! All devices are equipped with a large number of safety devices. If a fault occurs, you will be shown this on the display. In the event of a fault, leave the mains plug in so that the internal safety functions can continue to operate fully.
  • Page 22 Error number 6 or 9 Error number 15 Cause: Cause: The induced draught fan is not  The door is open for longer than 1 minute running at the correct rotation during operation speed  The damper at the bottom of the door is not in the right position The following circumstances might lead to this: ...
  • Page 23  The required combustion air cannot be Error number 24 supplied to the stove e.g. via a vapour extractor hood that is located in the Cause: vicinity of the installation site and is  Bottom flame temperature sensor switched on. defective or not connected ...
  • Page 24: General Faults

    11.2. General faults Fault: Cause: Correction: Stove will not ignite 1. The set target room Increase the target temperature. temperature is lower than the current room temperature (actual temperature); the “STANDBY” symbol appears on the display 2. Storage container is empty Refill storage container.
  • Page 25: Type Plate: Symbol

    Flue gas escaping 1. Power cut Ventilate room 2. Flue tubes or chimney Clean flue tube or chimney (fireplace) (fireplace) very dirty 12. Type plate: Symbol HAAS + SOHN OFENTECHNIK GMBH Urstein Nord 67, A-5412 Puch Pellet-Kaminofen Typenbezeichnung: 713.07 Variante: HSP 2.17 Wärmeleistungsbereich:...
  • Page 26 Figures 21: Replacement parts HSP 2.17 Figures 22: Replacement parts HSP 2.17...
  • Page 27: Replacement Parts List

    13. Replacement parts list HSP 2.17 Front plate cast left anthracite 0571307005120 Front plate cast right anthracite 0571307005130 Complete combustion chamber door black 0571207005300 Door hinge cast black 0571207005034 Glass panel 0571207005301 Sealing strip, glass panel 10x4 0040210040005 Sealing strip, combustion chamber door...
  • Page 28: Circuit Diagram

    14. Circuit diagram...
  • Page 29 No.: Description Cable harness Mains plug / mains filter Electric ignition Screw conveyor motor Induced draught 35/36 Flue gas temperature sensor 37/38 Flame temperature sensor 39/40 Room temperature sensor 41/42 Bottom flame temperature sensor 43/44 Door contact switch 48-50 Flue gas fan rotation speed Fuse T 3,15A ignition, induced draught fan, screw conveyor motor Fuse T 3,15A reserve Fuse T 0,315A operator console...
  • Page 30: Guarantee

    If there is no reference HAAS + SOHN gives no guarantee for damage to to type or manufacturer’s number in this place, or defects in devices or parts there of that have place enter them there.
  • Page 31 We accept no liability for changes made after going to press with these instructions. We reserve the right to make changes Our product range: Oil stoves Stoves Pellet stoves Tile stoves and slow combustion stoves for wood and coal Slow combustion stoves and auxiliary ranges for wood, coal and oil Fireplace inserts for wood Accessories for stoves and fireplaces Accessories for central oil supply...

Table of Contents