Advertisement

Quick Links

Pellet stove
Nameplate:
Installation and operating manual
Pellet stove
Installation and operating manual
Pellet stove
GB
0541908001409a

Advertisement

Table of Contents
loading

Summary of Contents for HAAS + SOHN HSP 8 CATANIA-II-RLU

  • Page 1 Installation and operating manual Pellet stove Pellet stove Nameplate: Installation and operating manual Pellet stove 0541908001409a...
  • Page 2 Please read through these operating instructions carefully. You will be informed about the function and handling of this stove and you will also save fuel and conserve the environment by heating correctly. The attached equipment sheet is part of these operating instructions. Notes in the text Of utmost importance there are the notes entitled WARNING.
  • Page 3: Table Of Contents

    Contents 1. General information ........................1 2. General safety information....................... 1 3. Electrical connection ......................... 2 4. Chimney ............................2 4.1. Weather conditions........................2 4.2. Chimney flue draft at rated heat output of the stove............. 3 4.3. Connection to the chimney ....................... 3 4.3.1.
  • Page 4 12. Power cut ..........................17 13. Cleaning and maintenance work (see Appliance sheet 3+4.) ........18 14. Faults, causes, correction ....................18 14.1. Fault – error code Fxxx ......................18 15. General information / faults ....................21 16. Warranty............................ 21 17.
  • Page 5: General Information

    1. General information • Please check the appliance for transport damage when unpacking it. In case of defects, please report these immediately to your stove dealer! • National and European standards, local regulations and those under building law as well as the relevant state building regulations or fire regulations must be complied with when installing, connecting and putting the fireplace into operation.
  • Page 6: Electrical Connection

    WARNING The stove must not be set up to be operated jointly with the home’s air conditioning and ventilation units. Note Exceptions: RLU certified appliances can also be operated with extractor hoods, vented tumble dryers and air conditioning and ventilation units if the stove has also been connected to a balanced flue. 3.
  • Page 7: Chimney Flue Draft At Rated Heat Output Of The Stove

    4.2. Chimney flue draft at rated heat output of the stove - if the minimum flue draft is not reached, then it is not possible to operate the fireplace properly and it will lead to increased contamination of the burner min.
  • Page 8: Installation

    Figure 1: Connection to the chimney: Chimney Effective length of the chimney Inlet of outside air T-shaped block with plug for discharge of condensate 5. Installation CAUTION For comfortable maintenance and service are following distances recommended: at the sides – minimum 50 cm at the back –...
  • Page 9: Minimum Gaps To Flammable Components

    5.1. Minimum gaps to flammable components CAUTION When installing the stove, it is essential to observe the official fire protection regulations. Please observe the national regulations to this effect. WARNING As the minimum distances from flammable or temperature-sensitive materials (E. G. furniture, wallpaper, wooden cladding) and from load-bearing walls, the specified gaps "at the back", "on the sides"...
  • Page 10: Outside Air Connection

    5.3. Outside air connection Note We recommend using the outside air connection for the supply of combustion air in order not to use up the valuable indoor air when heating. • To do this, connect the air intake elbow located on the back to a hose or a similar, suitable air duct or to a chimney system designed for this purpose.
  • Page 11: Operator Console Functions

    Note If the dimensions are lower than specified, then it is not possible to operate the fireplace properly and it will lead to increased contamination of the burner and inspection window. 6. Operator console functions 6.1. Buttons 6.1.1. Symbols on the display 10:34 Symbol : Stove is WLAN capable...
  • Page 12: Unsuitable Fuels

    • Identification: DINplus, ÖNorm M 7135, ENplus-A1 7.2. Unsuitable fuels • The use of lower-quality or unauthorised fuel adversely affects the operation of your pellet stove and may lead to the lapse of the guarantee. • Burning wood pellets of a poor quality leads to cleaning intervals becoming shorter and more fuel being consumed.
  • Page 13: Operating Console

    7.3.2. Operating console: 7.3.2.1. Software version As soon as the mains plug is connected, the software version ap- pears on the display for approx. 7 seconds, E.g.: Software HSP-6-V5.03 7.3.2.2. Language selection language After that you can select your required language. Procedure: language The required language is selected with the "Plus"...
  • Page 14: Additional Operator Console Functions

    7.3.2.5. Starting the pellet stove - operating mode ON Procedure: 10:34 On the standard screen, press the "On/Off" button to get the stove 26 °C started. Start zone 1 now appears under "Operating status" and the start 23 °C process begins. start zone 1 menu ON/OFF...
  • Page 15: Button Lock (Child Safety Device)

    Note Pressing any button makes the welcome page appear again on the display after approx. 3 seconds. 8.3. Button lock (child safety device) 10:34 Procedure: Activation: 28 °C Hold the Menu button down for approx. 10 seconds until "Button 23 °C block activated"...
  • Page 16: Operating Mode Weekly Prog. - Settings

    9.1.1. Operating mode Weekly prog. – settings Can only be selected on HSP 6, HSP 7, HSP 8, HSP 2 Premium and optionally with HSP 2 Home (in conjunction with WLAN module). oper. mode Procedure: b001 The week program function is selected with the "Plus" or "Minus" buttons.
  • Page 17: Setting The Language

    9.1.2. Setting the language main menu l001 Procedure: The required language can be set with the "Plus" or "Minus" language buttons. The setting is saved by pressing the "OK" button. deutsch To exit the function, press the "On/Off" button. englisch 9.1.3.
  • Page 18: Eco-Mode

    9.1.5. ECO-Mode g002 Procedure: main menu The required line can be selected with the "Plus" or "Minus" ECO-Mode buttons. The setting is saved by pressing the "OK" button. To exit the function, press the "On/Off" button. 9.1.6. Power Stage Blower (optional only on HSP 7) Power Stage Blower Procedure: The desired fan speed can be selected with the "Plus"...
  • Page 19: Contrast Brightness Display

    9.1.9. Contrast brightness display main menu Procedure: The required value can be selected with the "Plus" or "Minus" date/time buttons. language english The setting is saved by pressing the "OK" button. heating curve To exit the function, press the "On/Off" button. contrast 9.1.10.
  • Page 20: Heating Mode

    The whole "start zone" can go through up to 20 zones. It finishes after reaching a precisely defined temperature at the "flame temperature sensor" and the control system puts the stove into "Heating mode". The duration of the "start zone" can therefore vary. If, during the start zone, no flame generation can be achieved or the required temperature at the "flame temperature sensor"...
  • Page 21: Shut Down

    10.7. Shut down If a fault occurs, then a shut down is initiated. The components are switched on or off as follows: • Induced draught fan – ON and Screw conveyor – OFF and Ignition – OFF 10.8. Cooling The end of the shut down process depends on time and temperature. 10.9.
  • Page 22: Cleaning And Maintenance Work (See Appliance Sheet 3+4.)

    13. Cleaning and maintenance work (see Appliance sheet 3+4.) 14. Faults, causes, correction You can correct simple operating faults yourself with the following guide. For further information please consult your specialist dealer. WARNING If a fault occurs, you will be shown this on the display. In the event of a fault, do not pull the mains plug out straight away, so that the internal safety functions can continue to operate fully.
  • Page 23 G. Pellet fuel has too low a F. Screw motor defective - contact calorific value service department G. Clean burner - switch to high quality pellet type F006 A. Combustion chamber door A. Clean burner - close door open during operation B.
  • Page 24 F023 A. Flame temperature sensor A. Contact service department defective or not connected F024 A. Flame temperature sensor at A. Contact service department bottom defective or not connected F026 A. Pellet tank empty A. Fill pellet tank B. Burner not lying flush B.
  • Page 25: General Information / Faults

    The receipt is to be presented as evidence. If a defect occurs in your appliance within the warranty period, HAAS + SOHN will correct (repair) this defect in the shortest possible time or optionally replace the defective item. Cancellation of the contract /a reduction in price is excluded in so far as this does not conflict with the statutory regulations.
  • Page 26: Replacement Part Orders / Service Enquiries / Complaints

    17. Replacement part orders / Service enquiries / Complaints For ordering replacement parts or making enquiries about repairs and service as well as in the event of any complaints, please get in touch directly with your Haas +Sohn sales partner where you purchased the appliance.
  • Page 28 All documents such as operating instructions, appliance sheet, test reports etc. and contact details can also be found under: www.haassohn.com...

Table of Contents