F12345K
; Command sent to Analyzer: set center frequency to 12.345 MHz
F12345K
; Response from Analyzer: center frequency set to 12.345 MHz
B00K
; Command to Analyzer: report width and center frequency
...
;
464,
; Response: data point #96 ( @ 12.6 MHz) SWR = 4.64
477,
; Response: data point #97 ( @ 12.7 MHz) SWR = 4.77
488,
; Response: data point #98 ( @ 12.8 MHz) SWR = 4.88
502,
; Response: data point #99 ( @ 12.9 MHz) SWR = 5.02
515, K
; Response: data point #100 ( @ 13.0 MHz) SWR = 5.15, END
ZK
; Command to Analyzer: send the SWR data points
Z=
; Response from Analyzer
2006,
; Response: data point #1 ( @ 3.0 MHz) Z = 200.6 Ohms
1952,
; Response: data point #2 ( @ 3.1 MHZ) Z = 195.2 Ohms
1852,
; Response: data point #3 ( @ 3.2 MHz) Z = 185.2 Ohms
1787,
; Response: data point #4 ( @ 3.3 MHz) Z = 178.7 Ohms
...
;
...
; Response: data points #5 - #95...
...
; (not shown here, for clarity)
...
;
1116,
; Response: data point #96 ( @ 12.6 MHz) Z = 111.6 Ohms
1138,
; Response: data point #97 ( @ 12.7 MHz) Z = 113.8 Ohms
1160,
; Response: data point #98 ( @ 12.8 MHz) Z = 116.0 Ohms
1180,
; Response: data point #99 ( @ 12.9 MHz) Z = 118.0 Ohms
1205, K
; Response: data point #100 ( @ 13.0 MHz) Z = 120.5 Ohms, END
B99K
; Command to Analyzer: power off
; No response, Analyzer is powered off
B=
; Response from Analyzer
10,12345K
; Response: width = 10 kHz per data point, center frequency = 12.345
W7K
; Command to Analyzer: set width to 100 kHz per data point
W7K
; Response from Analyzer: width set to 100 kHz per data point
B00K
; Command to Analyzer: report width and center frequency
B=
; Response from Analyzer:
100,12345K
; Response: width = 100 kHz per data point, center frequency = 12.345
F08000K
; Command to Analyzer: set center frequency to 08.000 MHz
F08000K
; Response from Analyzer: center frequency set to 8.0 MHz
B01K
; Command to Analyzer: report SWR and Return Loss at center frequency
B=
; Response from Analyzer:
107,294K
; Response: SWR = 1.07, Return Loss = 29.4 dB