8. Electric Characteristics

Model
SCV-50EA
50Hz
SCV-70EA
50Hz
SCV-100EA
50Hz
SCV-120EA
SCV-140EA
SCV-160EA
Remark:
MCA: Min. Current Amps. (A)
TOCA: Total Over-current Amps. (A)
MFA: Max. Fuse Amps. (A)
MSC: Max. Starting Amps. (A)
RLA: Rated Current Amps. (A)
OFM: Outdoor Fan Motor
FLA: Full Load Amps. (A)
kW: Rated Motor Output (kW)
Outdoor Unit
Hz
Voltage
Phase
220~240V
1Ph
220~240V
1Ph
220~240V
1Ph
50Hz
380~415V
3Ph
50Hz
380~415V
3Ph
50Hz
380~415V
3Ph
Power Supply
Min.
Max.
MCA
TOCA
198V
264V
10.1
264V
10.1
198V
198V
264V
15.1
342V
456V
8.6
342V
456V
8.6
342V
456V
8.6
17
Compressor
MFA
MSC
RLA
14.6
20
29.5
8.1
15.6
20
29.5
8.1
25.0
30
52
12.1
8.9
15
44
6.9
9.6
15
44
6.9
10.1
15
44
6.9
OFM
kW
FLA
0.195
1.65
0.195
1.65
0.20
1.8
0.20
1.8
0.20
1.8
0.20
1.8