Neo-Neon International
Block access below the work area whenever installing or removing
the fixture.
UNPACKING
The packing material is carefully designed to protect the fixture during
shipment - always use it to transport the fixture.
The Neo One Mini comes with:
ELC 24V 250W lamp
3 m, 3-pin IEC mains cable
Attachment bracket for mounting clamp
User manual
AC
POWER
The Neo One Mini has switch-selectable settings to configure the power
supply for local conditions. Always use the setting that is closest to the
local AC supply.
Warning! For protection from electric shock, the fixture must be
grounded (earthed). The power supply shall have overload and
ground-fault protection.
Important! Install fuse and verify that power supply settings match
local
AC supply before use.
To change the voltage setting
1.
Disconnect the fixture from power.
2.
Remove the 4 base cover bolts with a 4 mm Allen wrench.
Move the cover out of the way of the switches without
disconnecting wires.
3.
Set the 5-position switch (A) to the setting closest to the AC
voltage. Use the higher setting if the voltage is halfway
between 2 settings. For example, use the 230 V setting
instead of the 210 V setting for operation with 220 V power.
4.
Set the 2-position switch (B) to the AC frequency (50 / 60
Hz).
5.
Replace the cover and apply a new power setting label to the
serial number label.