[Connection of the pedal of standing-work machine]
[Connection of the reactor box fan cord]
How to fix cable clip band
Panel
Pull
Push the hook.
Connect the connector of PK70 to connector
(CN39 : 12P) of SC-921 .
(Caution) Be sure to turn OFF the power before
connecting the connector.
Connect the connector of reactor box fan cord to
connector (CN62 : 6P) of SC-921.
(Caution) Be sure to turn OFF the power before
connecting the connector.
8) After inserting the connector, put all cords togeth-
er with cable clip band located on the side of
the box.
(Caution) 1. Fix the cord clamp and the cable clip
band following the attaching proce-
dure.
2. When removing the connector,
remove it from the wire saddle and
remove it while pressing the hook of
the cable clip band.
How to remove cable clip band
Panel
Push
Pushing the hook portion, push the band to remove it.
– 6 –