STANDARD INSTALLATION

47 1/2"
6"
3 1/8"
24"
(61)
(15.2)
(7.93)
1 9/16"
(3.97)
(12.7)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
5"
(12.7)
WATER
FRONT VIEW
W
SIDE VIEW
ANTI-TIP BRACkET
C
SOFFIT
SIDE VIEW INSTALLED
UNDER SOFFIT
42" Built-In Side-by-Side Refrigerator
(120.7)
20"
(50.8)
E
7/16"
(1.1)
Trim overlap
5"
75"
(190.5 )
From floor
to bottom
*84 1/2"
of electrical
area
(214.6)
*Trim will overlap
additional 7/16"
5"
3 1/2"
(12.7)
(8.9)
3 1/2"
(8.9)
D
STANDARD INSTALLATION
ZISB420DH
*Or installation
height from floor
SIDE VIEW INSTALLED
WITH WOODEN WALL STUDS
AND NO SOFFIT
ZISB480DX
TOP VIEW
24"
3 1/4"
(61.0)
(8.3)
1 1/2"
(3.8)
41 1/2"
(105.4)
20"
A
(50.8)
6"
E
(15.24)
5"
(12.7)
(190.5 )
From floor
to bottom
of electrical
5"
5"
3 1/2"
(12.7)
(12.7)
(8.9)
W
B
SIDE VIEW
WATER
FRONT VIEW
2" x 4"
Cut to 35" Length
Screws mounted
into vertical wall
studs
*84"
(213.4)
Top Case Trim
Install Screws
Through Trim and Into
3/4" Min. Wood Brace
FRONT VIEW INSTALLED
WITH METAL WALL STUDS
AND NO SOFFIT
STANDARD INSTALLATION
7/16"
(1.1)
Trim overlap
75"
area
3 1/2"
(8.9)
The refrigerator
will project
forward, slightly
beyond adjacent
cabinetry.
E
3/4"
Min.
Side View Top
Case Trim
Product Specification Revised 10/14
ZISB420DH
NOTES
A Mounting the junction
box in this location will
also allow for front
accessability through
access panel.
B Water supply area.
WARNING:
The refrigerator is top
heavy and must be secured
to prevent the possibility of
tipping forward. Failure to
do so may result in death
or serious injury.
The information below is
for cabinet design only.
When installing the anti-
tip system you must use
the product installation
instructions.
Determine your installation
construction and required
anti-tip configuration:
C Installed Under Soffit
After installing unit into
installation opening,
raise grille panel and
screw metal case sides to
adjacent cabinet. When
installed under a soffit,
the soffit cannot exeed 24"
deep. The top case trim
overlaps the bottom of the
soffit.
D Wooden Wall Studs and
No Soffit
• Cut a 2" x 4" block and
secure to brackets
provided.
• Secure brackets to back
wall of opening at 84" or
your installation height
from the floor.
E Metal Wall Studs and
No Soffit
This method requires
securely fastened cabinets
on both sides and a ¾"
minimum wood brace
above unit, with it's front
surface 24" from back wall.
• After installing unit into
opening, raise grille panel
and attach metal case
top trim to ¾" minimum
wood brace.
• The brace spanning
the enclosure must be
securely fastened to
cabinets on both sides.
See Installation
Instructions for detailed
instructions.