Error Messages

The following table details the cause and subsequent response of the appliance to errors.
Error Message
(flashing)
The inner temperature exceeds
HtA
the set maximum temperature
The inner temperature exceeds
LtA
the set minimum temperature
Short circuit or interruption of
PF1
the thermostat probe input line
Short circuit or interruption of
PF2
the evaporator probe input line
Inner temperature greater than
HLA
90°C
Inner temperature lower than
LLA
-45°C
The alarm message will end when the alarm trigger is no longer present, except PF1 and PF2 that require the appliance to be turned Off, then On again.

Technical Specifications

Model
Voltage
G596
230V 50Hz
G597
230V 50Hz
G598
230V 50Hz
G599
230V 50Hz
G600
230V 50Hz
G601
230V 50Hz
G621
230V 50Hz
G622
230V 50Hz
U636
230V 50Hz
U637
230V 50Hz
U638
230V 50Hz

Electrical Wiring

POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Compliance
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and
federal authorities.
POLAR products have been approved to carry the following symbol:
Cause
Display flashes
Alternating error message and current temperature
Display flashes
Alternating error message and current temperature
Display flashes
Display flashes
Display flashes
Alternating error message and current temperature
Display flashes
Alternating error message and current temperature
Temperature
Power
Current
Range
340W
1.5A
-2°C to 10°C
340W
1.5A
-2°C to 10°C
450W
2A
-2°C to 10°C
1000W
4.35A
-10°C to -20°C
1000W
4.35A
-10°C to -20°C
1000W
4.35A
-10°C to -20°C
340W
1.5A
-2°C to 10°C
340W
1.5A
-2°C to 10°C
250W
1A
-2°C to 10°C
250W
1A
-2°C to 10°C
250W
1A
-2°C to 10°C
Appliance Response
Capacity
Refrigerant
(litres)
282
R134a 240g
417
R134a 240g
563
R134a 250g
282
417
563
417
R134a 240g
368
R134a 250g
240
R134a 165g
240
R134a 165g
240
R134a 165g
4
Action
Check Troubleshooting Guide
If problem persists call POLAR agent or
qualified Technician
Check Troubleshooting Guide
If problem persists call POLAR agent or
qualified Technician
Compressor operates as specified by
parameter '=23'
Defrost as specified by parameters d8 and d9
Call POLAR agent or qualified Technician
Call POLAR agent or qualified Technician
Dimensions
H x W x D (mm)
850 x 1360 x 700
850 x 1795 x 700
850 x 2230 x 700
R404 300g
850 x 1360 x 700
R404 260g
850 x 1795 x 700
R404 320g
850 x 2230 x 700
900 x 900 x 700
850 x 1365 x 700
850 x 900 x 700
850 x 900 x 700
850 x 900 x 700
UK
Weight
(Kg)
98
134
153
103
136
155
140
107
70
71
72

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G597G598G599G600G601G621 ... Show all

Table of Contents