Page 2
Telephone Helpline: 1300225960 Safety Tips • Position on a flat, stable surface. • A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product. • Consult Local and National Standards to comply with the following: - Health and Safety at Work Legislation - Fire Precautions...
Page 3
Product Description GD882-A - POLAR Stainless Steel Preparation Counter GD883-A - POLAR Stainless Steel Preparation Counter Introduction Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.
Page 4
Telephone Helpline: 1300225960 Installation Set the Operating Temperature 1. Hold the SET button for 3 seconds. The value Note: If the unit has not been of the current set point will be displayed. stored or moved in an upright 2. Press the buttons to display the position, let it stand upright for required temperature.
Page 5
Telephone Helpline: 1300225960 Troubleshooting If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer. Fault Probable Cause Solution The appliance is not The unit is not switched on Check the unit is plugged in correctly and working switched on...
Page 6
Telephone Helpline: 1300225960 Technical Specifications Temperature Dimensions Weight Model Voltage Power Current Refrigerant Range H x W x D mm (kg) GD882-A 230V 300W 2.5A 0°C - 5°C R134a 270g 1080 x 1225 x 50Hz GD883-A 230V 450W 3.8A 0°C - 5°C...
Need help?
Do you have a question about the GD882-A and is the answer not in the manual?
Questions and answers