Error Messages
The following table details the cause and subsequent response of the appliance to errors.
Error Message
(flashing)
The inner temperature exceeds
HtA
the set maximum temperature
The inner temperature exceeds
LtA
the set minimum temperature
Short circuit or interruption of
PF1
the thermostat probe input line
Short circuit or interruption of
PF2
the evaporator probe input line
Inner temperature greater than
HLA
90°C
Inner temperature lower than
LLA
-45°C
The alarm message will end when the alarm trigger is no longer present, except PF1 and PF2 that require the appliance to be turned Off, then On again.

Technical Specifications

Model
Voltage
G604
230V 50Hz
G605
230V 50Hz
G606
230V 50Hz
G607
230V 50Hz

Electrical Wiring

POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Disposal
EU regulations require refrigeration product to be disposed of by specialist companies who remove or recycle all gasses, metal and plastic components.
Consult your local waste collection authority regarding disposal of your appliance. Local authorities are not obliged to dispose of commercial refrigeration
equipment but may be able to offer advice on how to dispose of the equipment locally.
Alternatively call the POLAR helpline for details of national disposal companies within the EU.
Compliance
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and
federal authorities.
POLAR products have been approved to carry the following symbol:
Cause
Display flashes
Alternating error message and current temperature
Display flashes
Alternating error message and current temperature
Display flashes
Display flashes
Display flashes
Alternating error message and current temperature
Display flashes
Alternating error message and current temperature
Temperature
Power
Current
Range
340W
1.5A
2°C to 10°C
340W
1.5A
2°C to 10°C
340W
1.5A
2°C to 10°C
340W
1.5A
2°C to 10°C
Appliance Response
Refrigerant
R134a 165 grams
R134a 280 grams
R134a 165 grams
R134a 280 grams
4
Action
Check Troubleshooting Guide
If problem persists call POLAR agent or
qualified Technician
Check Troubleshooting Guide
If problem persists call POLAR agent or
qualified Technician
Compressor operates as specified by
parameter '=23'
Defrost as specified by parameters d8 and d9
Call POLAR agent or qualified Technician
Call POLAR agent or qualified Technician
Dimensions
Weight
H x W x D (mm)
(Kg)
900 x 900 x 700
100
1050 x 1435 x 700
140
850 x 900 x 700
70
850 x 1360 x 700
130