Troubleshooting; Technical Specifications; Electrical Wiring - Polar Refrigeration DL893-A Instruction Manual

Cabinet refrigerators/freezers
Table of Contents

Advertisement

Telephone Helpline: 1300225960

Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer.
Fault
The appliance is not working
The appliance turns on, but the
temperature is too high/low
The appliance is leaking water
The appliance is unusually loud

Technical Specifications

Model
Voltage
DL893-A
220-240V 50Hz
DL894-A
220-240V 50Hz
DL895-A
220-240V 50Hz
DL896-A
220-240V 50Hz
DL897-A
220-240V 50Hz
DL898-A
220-240V 50Hz
DL899-A
220-240V 50Hz
CK480-A
220-240V 50Hz

Electrical Wiring

.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Too much ice on the evaporator
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat source or air flow to
the condenser is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being stored in the
appliance
Appliance is overloaded
The appliance is not properly levelled
The discharge outlet is blocked
Movement of water to the drain is obstructed
The water container is damaged
The drip tray is overflowing
The safety band has not been removed
Loose nut/screw
The appliance has not been installed in a level or
stable position
Temperature
Power
Current
Range
380
2.3A
-2°C to 10°C
600
2.8A
-15°C to -22°C
700
3.3A
-2°C to 10°C
700
3.3A
-15°C to -22°C
700
3.3A
-15°C to -22°C
700
3.3A
-2°C to 10°C
380
2.3A
-2°C to 10°C
600
2.8A
-15°C to -22°C
Check the unit is plugged in correctly and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Defrost the appliance
Clean condenser with hose attachement of vacuum
Check doors are shut and seals are not damaged
Move the refrigerator to a more suitable location
Increase ventilation or move appliance to a cooler position
Remove any excessive hot foodstuffs or blockages to the fan
Reduce the amount of food stored in the appliance
Adjust the screw feet to level the appliance (if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if applicable)
Call POLAR agent or qualified Technician
Empty the drip tray (if applicable)
Remove the safety band
Check and tighten all nuts and screws
Check installation position and change if necessary
Capacity
Refrigerant
(litres)
600
R134a 300g
600
R404a 360g
1200
R134a 320g
1200
R404a 450g
1200
R404a 450g
1200
R134a 320g
600
R134a 300g
600
R404a 360g
Action
Dimensions
Weight
H x W x D (mm)
(kg)
2010 x 680 x 850
145
2010 x 680 x 850
148
2010 x 1340 x 850
195
2010 x 1340 x 850
198
2010 x 1340 x 850
198
2010 x 1340 x 850
195
2010 x 680 x 850
145
2010 x 680 x 850
148
4