Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer.
Fault
The appliance is not
The unit is not switched on
working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The appliance turns on, but
Too much ice on the evaporator
the temperature is too high/
Condenser blocked with dust
low
Doors are not shut properly
Appliance is located near a heat source or air flow to the
condenser is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being stored in the appliance
Appliance is overloaded
The appliance is leaking
The appliance is not properly levelled
water
The discharge outlet is blocked
Movement of water to the drain is obstructed
The water container is damaged
The drip tray is overflowing
The appliance is unusually
Loose nut/screw
loud
The appliance has not been installed in a level or stable
position

Technical Specifications

Model
Voltage
Power
GD882
230V 50Hz
300W
GD883
230V 50Hz
450W

Electrical Wiring

POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Probable Cause
Temperature
Current
Refrigerant
Range
2.5A
0°C to 5°C
R134a 270
3.8A
0°C to 5°C
R134a 300g
Check the unit is plugged in correctly and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Defrost the appliance
Call POLAR agent or qualified Technician
Check doors are shut and seals are not damaged
Move the refrigerator to a more suitable location
Increase ventilation or move appliance to a cooler position
Remove any excessive hot foodstuffs or blockages to the fan
Reduce the amount of food stored in the appliance
Adjust the screw feet to level the appliance (if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if applicable)
Call POLAR agent or qualified Technician
Empty the drip tray (if applicable)
Check and tighten all nuts and screws
Check installation position and change if necessary
Dimensions
Weight (kg)
H x W x D (mm)
1080 x 1225 x 770
138