Adapting Microwave Blower - GE PVM1899 Installation Instructions Manual

Above the cooktop microwave oven
Hide thumbs Also See for PVM1899:
Table of Contents

Advertisement

Adapting microwave blower

This microwave is shipped assembled for Room Venting
Installation. The blower unit is already in place and must not
to be adapted.
Adapting microwave blower for roof venting
1. Remove and save the screws holding the blower motor and
the blower plate. Lift up the blower plate and put it aside.
2. Carefully pull out the blower unit and rotate 90º so that fan
blade openings are facing out the top of the microwave.
3. Place the blower unit back into the opening.
CAUTION
Do not pull or stretch the blower unit wiring. Make
sure the wires are not pinched, and that they are
properly secured.
4. Replace the blower plate and secure with the screws
removed in step 1.
5. Attach the exhaust adapter to the top of the blower plate
by sliding it into the guides. Push in securely until it is in the
locking tabs. Make sure the damper hinge swings freely.
Installation Instructions
9
Adapting microwave blower for wall venting
1. Remove and save the screws holding the blower motor and
the blower plate. Lift up the blower plate and put it aside.
2. Carefully pull out the blower unit and rotate 90º so that fan
blade openings are facing out the top of the microwave.
3. Rotate the blower unit counterclockwise 180º.
4. Gently remove the wires from the grooves. Reroute the
wires through the grooves on other side of the blower
unit. Rotate blower unit 90º so that fan blade openings are
facing out the back of the microwave.
CAUTION
Do not pull or stretch the blower unit wiring. Make
sure the wires are not pinched, and that they are
properly secured.
5. Place the blower unit back into the opening.