Removing The Lc-Sc Cable Adapter Protective Caps - IBM DS3500 Installation, User's, And Maintenance Manual

System storage
Table of Contents

Advertisement

CAUTION:
This product might contain one or more of the following devices: CD-ROM drive, DVD-ROM drive,
DVD-RAM drive, or laser module, which are Class 1 laser products. Note the following information:
v Do not remove the covers. Removing the covers of the laser product could result in exposure to
hazardous laser radiation. There are no serviceable parts inside the device.
v Use of the controls or adjustments or performance of procedures other than those specified herein
might result in hazardous radiation exposure.
(C026)
CAUTION:
Data processing environments can contain equipment transmitting on system links with laser modules
that operate at greater than Class 1 power levels. For this reason, never look into the end of an optical
fiber cable or open receptacle. (C027)
Connecting an LC-SC cable adapter to a device:
To connect an LC-SC Fibre Channel cable adapter to a device, complete the following steps.
1. Read the information in "Handling fiber optic cables" on page 3-5.
2. Connect one end of an LC-LC cable to an SFP module in the DS3500. For instructions, see "Using
LC-LC Fibre Channel cables" on page 3-9.
3. Remove the two protective caps from the LC connector end of the LC-SC cable adapter as shown in
Figure 3-18. Save the protective caps for future use.
Figure 3-18. Removing the LC-SC cable adapter protective caps
4. Carefully insert the other end of the LC-LC cable into the LC connector end of the LC-SC cable
adapter as shown in Figure 3-19 on page 3-14. Push in the connector until it clicks into place.
Chapter 3. Cabling the storage subsystem and storage enclosure