Cedarbrook
S auna
+ Steam – Family
o wned
a nd
o perated
s ince
1 971 We build cedar saunas , kits, sauna doors , accessories for commercial saunas & residential sauna rooms —...
Heater Model __________ Serial # __________ I n s t a l l a t i o n G u i d e ULTRA-SAUNA HEATER Proudly made in USA since 1964 LARGE HEATERS 12.0-18.0 KW Installation Instructions & User Manual PO Box 636 Eagle Idaho USA.
240 sq ft (73 sq m) SAUNA ROOM VENTING GUIDELINES Sauna room should be vented according to manufacturer’s specifications or Scandia sauna room specification found in the Scandia sauna installation instructions. Improper ventilation is dangerous for the sauna user’s health. When the door is under cut, there is no other venting required in small sauna rooms.
Minimum dimensions of heater guard must be 42” L x 26” d x 39” H—Top rail of guard must be below heater vent CONTROL PANEL MODELS AND SIZES A/B control: suitable for heater models 75240, 75208, E control: suitable for heater models 12240, 12208, A/B Control Rough -In Dimensions E/E24 Control Rough -In Dimensions 90240, 90208, 12208-3...
Page 5
C o n tro ls b e h in d c o v e r (2 4 ho u r mounted. Scandia sales (2 4 ho u r tim er) tim er) representative. H e a te r...
WIRING DIAGRAMS A3 Controls (60 minute timer) 9000 Wa tts to 120 00 Wa tts Hea ters Three-phase only 240/208 Volts Series Watts Volts Amps Phase Mas Room Size Circuit Breaker Supply Wires (incl ground) Wires from control to heater 80 sq ft 4 qty #8 ga 4 qty #8 ga - 2 qty #14...
Page 7
WIRING DIAGRAMS E2 Controls (60 minute timer) 12000‐18000 Watt 240/208 Volt single phase Watts Voltage Amps Phase Max Room Size Circuit Breaker Wires (Control to Heater) Supply Wires (Inc.Ground) 12000 240/208 50 / 57.7 1 120 sq ft 60 / 70 240 3 #6 / 208 3 #4 7 qty #10 ‐ 2 qty #14 15000 240/208 62.5 / 72.2 1 180 sq ft 70 / 90 240 3 #4 / 208 3 #2 7 qty #10 ‐ 2 qty #14 E 2 C o n t r o l f o r S c a n d i a / V i c o 1 2 K W , 1 5 K W a n d 1 8 K W H e a t e r S e rie s W a tts V o lts...
Page 8
WIRING DIAGRAMS E2 Controls (60 minute timer) 12000‐18000 Watt 240/208 Volt single phase ‐ T‐Models Converting 60 minute timer to 24 hr programmable timer. Watts Voltage Amps Phase Max Room Size Circuit Breaker Wires (Control to Heater) Supply Wires (Inc.Ground) 12000 240/208 50 / 57.7 1 120 sq ft 60 / 70 240 3 #6 / 208 3 #4 7 qty #10 ‐ 2 qty #14 15000 240/208 62.5 / 72.2 1 180 sq ft 70 / 90 240 3 #4 / 208 3 #2 7 qty #10 ‐ 2 qty #14 E 2 C o n t r o l f o r S c a n d i a / V i c o 1 2 K W , 1 5 K W a n d 1 8 K W H e a t e r S e rie s W a tts V o lts...
Page 9
WIRING DIAGRAMS Converting 60 minute timer to 24 hr programmable timer. T -s ta t C o n ta c to r c o n t a c t or c o il s T i m e r c o n t a c t or c o il s C o n ta c t o r T o H i g h...
Product Liability: The buyer acknowledges that the goods sold to them by Scandia Manufacturing can cause property damage and personal injury if not properly sized, handled or installed. The buyer further agrees to indemnify and hold harmless Scandia Manufacturing from any or all claims for damage, loss and/or liability arising out of improper handling, siz- ing and/or installation of goods.
Page 11
Programming Instructions 24 digital hour timer To Set or Change the Day and Time: To clear entire memory, press key. Hold down the CLOCK key while pressing either the DAY, HOUR or MINUTES keys. Continue pressing until the desired day or number is shown. Then simply lift finger off of the CLOCK key to set.
In commercial locations, Scandia will provide a one-year warranty on the unit. (3) During the first year SCANDIA will, at its option, repair or exchange at the Factory all parts which it finds have become inoperative during said warranty period due to a defect in material or workmanship, without cost to cus- tomer except for freight and/or crating charges.
Need help?
Do you have a question about the 12240 and is the answer not in the manual?