Table of Contents

Advertisement

Quick Links

Instruction Manual
TMSSC2
604-Pin Socket Hardware Support
071-1345-00
www.tektronix.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMSSC2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tektronix TMSSC2

  • Page 1 Instruction Manual TMSSC2 604-Pin Socket Hardware Support 071-1345-00 www.tektronix.com...
  • Page 2 Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077...
  • Page 3 Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
  • Page 4 In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period. If Tektronix is unable to provide a replacement that is free from defects in materials and workmanship within a reasonable time thereafter, Customer may terminate the license for this software product and return this software product and any associated materials for credit or refund.
  • Page 5: Table Of Contents

    ........3- -1 To Extract Channel Assignments and Groups ..... . . 3- -1 TMSSC2 604-Pin Socket Support...
  • Page 6 ........4- -2 Index TMSSC2 604-Pin Socket Support...
  • Page 7 ..... . 2- -6 Table 2- -5: Certifications and compliances ..... 2- -7 TMSSC2 604-Pin Socket Support...
  • Page 8 Table of Contents TMSSC2 604-Pin Socket Support...
  • Page 9: General Safety Summary

    Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. Provide Proper Ventilation. Refer to the manual’s installation instructions for details on installing the product so it has proper ventilation. TMSSC2 604-Pin Socket Support...
  • Page 10 WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. Symbols on the Product. The following symbols may appear on the product: CAUTION WARNING Protective Ground Refer to Manual High Voltage (Earth) Terminal TMSSC2 604-Pin Socket Support...
  • Page 11: Service Safety Summary

    Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components. To avoid electric shock, do not touch exposed connections. TMSSC2 604-Pin Socket Support...
  • Page 12 Service Safety Summary TMSSC2 604-Pin Socket Support viii...
  • Page 13: Preface

    If you are not familiar with operating microprocessor support packages, you need to supplement this instruction manual with information on basic operations from the Tektronix logic analyzer online help to set up and run the support package. Manual Conventions This manual uses the following conventions: H A pound sign (#) following a signal name indicates an active low signal.
  • Page 14: Contacting Tektronix

    This phone number is toll free in North America. After office hours, please leave a voice mail message. Outside North America, contact a Tektronix sales office or distributor; see the Tektronix web site for a list of offices. TMSSC2 604-Pin Socket Support...
  • Page 15: Getting Started

    Getting Started...
  • Page 17: Product Description

    TMSSC2 604-Pin Socket probe adapter is the following software: PUB32G10 PUB32G8N8 NOTE. The TMSSC2 probe adapter is compatible with the TMS117 and the TMS122 software support packages. These software support packages are available only to customers with a valid, restricted, secret nondisclosure agreement (RS-NDA) with Intel.
  • Page 18: P6860 Probes

    P6860 probes in the logic analyzer online help. LAI Cables You can use the TLA7AXX, 235 MHz logic analyzer modules and logic analyzer interface (LAI) cables to connect to the TMSSC2 probe adapter. The LAI cables (012-1661-XX) are specifically designed for use with the TMSSC2 probe adapter.
  • Page 19: Labeling P6860 Probes

    Apply labels using the instructions described in the P6860 High Density Logic Analyzer Probe Label Instructions, Tektronix part number 071-1123-XX. This manual can be accessed from the Tektronix.com web site. This information is also located in the logic analyzer online help.
  • Page 20: Configure The Preprocessor Unit

    Table 1- 1: Software selection Software support 1- - 2 PUB32G8N8 or TMS117 2- - 3 PUB32G10 TMS122 Software support selector Figure 1- 2: Selecting your software on the preprocessor unit TMSSC2 604-Pin Socket Support 1- 4...
  • Page 21: Connecting The Logic Analyzer To A Target System

    To prevent harm to yourself or damage to the preprocessor unit, do not open the preprocessor unit. There are no operator serviceable parts inside the preproces- sor unit. Refer servicing of internal parts in the preprocessor unit to Tektronix authorized personnel only. External parts may be replaced by qualified service personnel.
  • Page 22: Figure 1- 3: Removing Microprocessor Probe Head From The Target System

    Remove the heatsink Remove the microprocessor from the target system. Open the load lever. Target system Figure 1- 3: Removing microprocessor probe head from the target system TMSSC2 604-Pin Socket Support 1- 6...
  • Page 23: Figure 1- 4: Attach The Probe Head To The Target System

    LIF socket. Attach four bottom heat sink brackets and screws to the target system. (torque to 8 in- - lbs) Target system Figure 1- 4: Attach the probe head to the target system TMSSC2 604-Pin Socket Support 1- 7...
  • Page 24: Figure 1- -5: Attaching The Heat Sink Brackets And Microprocessor To The Target System

    Install the microprocessor. Pin 1 (notched corner) Figure 1- 5: Attaching the heat sink brackets and microprocessor to the target system TMSSC2 604-Pin Socket Support 1- 8...
  • Page 25: Figure 1- 6: Attaching The Heat Sink To The Target System

    Attach the probe head cables to the preprocessor unit cables (snap into place). Figure 1- 6: Attaching the heat sink to the target system TMSSC2 604-Pin Socket Support 1- 9...
  • Page 26: Removing The Microprocessor

    It is not necessary to power off the logic analyzer. 2. Reverse the steps in Figures 1- -3 through 1- -6 to remove the probe head. 3. Store the probe head in the original packing material (see page 1- -17). TMSSC2 604-Pin Socket Support 1- 10...
  • Page 27: Applying Lai Labels

    Align and place the labels in the label indents, as shown in step 1. Repeat for all steps. Probe-head LAI cable Blank Module end Match the color and the channel name Blank Figure 1- 8: Apply LAI labels TMSSC2 604-Pin Socket Support 1- 11...
  • Page 28: Connect The Probes And Lai Cables

    1- -14. Figure 1- -9 shows a P6860 probe, an LAI Cable, and a preprocessor unit. If you need to apply labels to the LAI cables, see page 1- -11 P6860 probe LAI cable Preprocessor unit Figure 1- 9: LAI cable, P6860 probe, and preprocessor unit TMSSC2 604-Pin Socket Support 1- 12...
  • Page 29: Figure 1- 10: Lai Cable, P6860 Probe, And Module Configurations

    All signals, except timing signals Four P6860 Six LAI cables One P6860 probe probe and (Timing signals) one LAI cable PUB32G10 or PUB32G8N8 TMS117_5W or TMS122_5W Figure 1- 10: LAI cable, P6860 probe, and module configurations TMSSC2 604-Pin Socket Support 1- 13...
  • Page 30: Lai Cable And P6860 Probe Connections (Four Modules)

    LED lights on the front of the preprocessor unit, indicating that the probe adapter is active. 5. Power on the target system. To remove power from the target system and the probe adapter, reverse the preceding steps. You can skip step 1. TMSSC2 604-Pin Socket Support 1- 14...
  • Page 31: Logic Analyzer Software Compatibility

    NOTE. Before you install any software, it is recommended you verify that the microprocessor support software is compatible with the logic analyzer software. To install the software on your Tektronix logic analyzer, follow these steps: 1. Insert the disk in the disk drive.
  • Page 32: Care And Maintenance

    There are no operator serviceable parts inside the preprocessor unit. Refer servicing of internal parts in the preprocessor unit to Tektronix authorized personnel only. External parts may be replaced by qualified service personnel. Fuses All fuses located in the preprocessor unit are not replaceable by the customer (operator).
  • Page 33: Short-Term Storage

    3. Using antistatic nongenerating tape, tape the pin-protector board onto the pin header on the bottom of the probe head. 4. Store the probe head in the black case it was shipped in. Figure 1- 11: Nonspecific probe head and case TMSSC2 604-Pin Socket Support 1- 17...
  • Page 34: Long-Term Storage

    1- -12 through 1- -14. Place the foam end caps on both sides of the preprocessor unit. Figure 1- 12: Place preprocessor unit in the cardboard carton Figure 1- 13: Place cables in the cutouts TMSSC2 604-Pin Socket Support 1- 18...
  • Page 35: Shipping The Probe Adapter

    3 inch (7.62 cm) minimum on all sides of the product. 2. If you are shipping a probe adapter to a Tektronix service center for Warranty service, attach a tag to the probe adapter showing the following: H Owner’s name and address...
  • Page 36 Getting Started TMSSC2 604-Pin Socket Support 1- 20...
  • Page 37: Specifications

    Specifications...
  • Page 39: Circuit Description

    The ASIC latches these signals using the rising edge of BCLK. Derived Signals The TMSSC2 probe adapter hardware derives several custom signals from the front-side bus signals captured by the ASIC. These signals are used by the logic analyzer support software to provide clocking, transaction phase linking, and disassembly.
  • Page 40 Signal Probing The TMSSC2 probe adapter uses passive series isolation to acquire data. Bus Tracking Logic The TMSSC2 probe adapter uses a bus tracking PAL to aid the disassembly software in linking various bus phases. Common Clock The IA32G8N8 and IA32G10 software allows disassembly from a data bus operating at the common clock rate specified in Table 2- -1.
  • Page 41: Loading Diagrams

    --0.58dB@1.7GHz 75 Ω 75 Ω ~44’’ ~1300 mils 4.18 ns 213 ps Mated Receiver Samtec 0.7 pF 0.7 pF 0.4 pF Figure 2- - 1: Probe adapter preliminary load model for typical signals TMSSC2 604-Pin Socket Support 2- - 3...
  • Page 42: Figure 2- -2: Pin Header Electrical Load Model For Typical Signals

    0.5 pF Figure 2- - 4: Mated Samtec model TD=83 ps TD=5 ps Z0=75 Ω Z0=100 Ω 0.2 Ω 450 fF 225 fF 75 Ω VREF~0.8 V Figure 2- - 5: Receiver Model TMSSC2 604-Pin Socket Support 2- - 4...
  • Page 43: Specification Tables

    Specifications Specification Tables These specifications are for a probe adapter connected between a compatible Tektronix logic analyzer and a target system. Signal voltage swing in your target system must be at least 600 mV around the GTL+ reference voltage. NOTE. The functionality and specifications are not guaranteed for the prototype product.
  • Page 44: Table 2- -2: Electrical Specifications For The Ac Input To The

    5.08 cm (2 in) Back 7.62 cm (3 in) Bottom, right side 0.635 cm (0.250 in) Designed to meet Tektronix standard 062-2847-00 class 5. microprocessor Not to exceed thermal considerations. Customer supplied cooling might be required across the CPU. TMSSC2 604-Pin Socket Support...
  • Page 45: Table 2- -5: Certifications And Compliances

    Mains input: Overvoltage Category II (as defined in IEC 61010-1, Annex J) All other inputs and outputs: 5 V maximum Pollution Degree Descriptions Pollution Degree 2 (as defined in IEC 61010-1). Note: Rated for indoor use only. TMSSC2 604-Pin Socket Support 2- - 7...
  • Page 46: Figure 2- -6: Dimensions Of The Probe Head

    Specifications Dimensions Figure 2- -6 shows the dimensions of the probe head. 61.04 mm (2.403 in) 53.721 mm (2.115 in) 8.02 mm (0.316 in) Figure 2- - 6: Dimensions of the probe head TMSSC2 604-Pin Socket Support 2- - 8...
  • Page 47: Figure 2- -7: Dimensions Of The Preprocessor Unit

    Figure 2- - 7). 474.32 mm (18.674 in) 425.45 mm (16.750 in) 420.37 mm (16.550 in) 139.70 mm 160.27 mm (5.500 in) (6.310 in) Figure 2- - 7: Dimensions of the preprocessor unit TMSSC2 604-Pin Socket Support 2- - 9...
  • Page 48 Specifications TMSSC2 604-Pin Socket Support 2- - 10...
  • Page 49: Reference

    Reference...
  • Page 51: Reference Tables

    Reference Tables The TMSSC2 product software provides reference files of the symbol and channel group tables. Viewing the tables is not a requirement when preparing the module for use. You can view the reference tables without connecting the Tektronix logic analyzer to your target system.
  • Page 52: Figure 3- 1: Channel Setup Export Window

    Tab is the default. Refer to the logic analyzer online help for more information about delimiters. Figure 3- 1: Channel Setup Export window 3. Select Export. Locate and view the exported ChannelSetup.txt file. TMSSC2 604-Pin Socket Support 3- 2...
  • Page 53 Replaceable Parts List...
  • Page 55: Parts Ordering Information 4

    For more information about the module exchange program, call 1-800-833-9200. Outside North America, contact a Tektronix sales office or distributor; see the Tektronix web site for a list of offices: www.tektronix.com. Module Repair and Return. You may ship your module to us for repair, after which we will return it to you.
  • Page 56: Using The Replaceable Parts List 4

    Using the Replaceable Parts List This section contains a list of the mechanical and/or electrical components that are replaceable for the TMSSC2 Hardware Support package. Use this list to identify and order replacement parts. The following table describes each column in the parts list.
  • Page 57 10156 TORINO~VAICENTALLO~62/456 ITALY, TK2548 XEROX CORPORATION 7431 EVERGREEN PARKWAY HILLSBORO, OR 97124 TK6121 TUMBLER CORP 4241 BUSINESS CENTER DR FREMONT, CA 94538 TK6585 TRESKE PRECISION MACHINE INC 14140 SW GALBREATH DRIVE SHERWOOD, OR 97140 TMSSC2 604-Pin Socket Support 4- - 3...
  • Page 58 Serial no. Mfr. index number effective discont’d Name & description code Mfr. part number number 4--1--1 672--5706--50 CIRCUIT BD ASSY; TMSSC2 PROBE HEAD BOARD 80009 672--5706--50 W/CABLES & PADDLE BD;TESTED 361--1807--00 SPACER;HEATSINK ATTACH;TEJAS TK6585 361--1807--00 200--4861--00 COVER; BOTTOM,HEATSINK ATTACH;TEJAS TK6585 200--4861--00 200--4862--00 COVER,TOP;...
  • Page 59: Figure 4- -1: Probe Adapter Exploded View

    Replaceable Parts List Figure 4- - 1: Probe adapter exploded view TMSSC2 604-Pin Socket Support 4- - 5...
  • Page 60: Figure 4- -2: Preprocessor Unit Exploded View

    Replaceable Parts List (Return the prepro- cessor unit to the factory for service) Figure 4- - 2: Preprocessor unit exploded view TMSSC2 604-Pin Socket Support 4- - 6...
  • Page 61 Index...
  • Page 63 Modules connections, 1- -2 AC adapter, 2- -6 BCKL timing, 2- -6 clock rate, 2- -5 power requirements, 2- -5 setup time, 2- -5 Options, 1- -3 source synchronous capture, disabled, 2- -5 TMSSC2 604-Pin Socket Support Index- - 1...
  • Page 64 Restrictions, 1- -3 address bus, 1- -3 clock rate, 1- -3 data bus, 1- -3 URL, Tektronix, x disabling the cache, 1- -4 Web site address, Tektronix, x Service support, contact information, x TMSSC2 604-Pin Socket Support Index- - 2...

Table of Contents