Kenwood KH600B-IND Instructions For Use Manual page 30

Touch control induction cooking hobs
Table of Contents

Advertisement

CONNECTING THE FEEDER CABLE
To connect the feeder cable to the hob it is necessary to carry out the following operations:
Unhook the terminal board cover "A" by inserting a screwdriver into the two hooks "B"
(fig. 5.1).
Unscrew the screw "C" and open completely the cable clamp "D" (fig. 5.1).
Connect the phase, neutral and earth wires to terminal board "E" according to the
diagram in fig. 5.2a or 5.2b.

The U bolt "F" shall be used or not depending on the type of connection; it is supplied
already fitted to the terminals or inside the terminal board, close to the cable clamp "D" .
Strain the feeder cable and block it with cable clamp "D" (by screwing screw "C") .
Close the cover "A" of the terminal board "E" (check the two hooks "B" are correctly
hooked) .
FEEDER CABLE SECTION
"Type H05RR-F, H05VV-F or H05V2V2-F"
220-240 V ac
380-415 V 2N ac
380-415 V 3N ac
(*) Connection with wall box connection
– Diversity factor applied
– A diversity factor may be applied to the total loading of the appliance only by a
suitably qualified person
(**) Same diagram as per fig. 5.2b (380-415 V 2N ac) but with one phase not connected
on the electrical mains supply
(***) The maximum power limit of the appliance can be reduced as indicated in chapter
"MAXIMUM POWER MANAGEMENT"
If the supply cord (not supplied with the appliance) is damaged, it must be replaced
by the manufacturer or its service agent or a similarly qualified person in order to
avoid a hazard.
30
3 x 2,5 mm
(*)
2
4 x 1,5 mm
(*)
2
5 x 1,5 mm
(*) (**)
2
induction power=6800 watt max (***)
induction power=6800 watt max (***)
induction power=6800 watt max (***)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents