Purpose of this Manual This document is the A7502 User's Manual; it contains information about the installation, the configuration and the use of the device. Change Document Record Date Revision Changes 19 October 2016 Initial release 27 October 2016 New characteristics graphics...
Electronic Instrumentation Index ........................... 4 ..................................4 ....................5 ....................9 .......................9 ........................10 ................................10 List of Figures ....................................4 ................................6 ............................6 .........................7 ..............................7 ..............................7 .............................8 ............................8 ................................10 ............................10 List of Tables ..............................4 ..............................5 ........................9 ........................9 UM5555 – A7502 User Manual Rev. 3...
Page 4
Electronic Instrumentation 1 Overview The CAEN Mod. A7502 is a compact high efficiency power supply providing a programmable and monitorable output voltage ranging from 0 to 2100 V, when supplied with a +5 V input. It is available with either positive or negative output voltage.
Over current short circuit, sparks and humidity Tab. 2: A7502 Technical Specifications N.B.: In parallel to the load we have a 300 MΩ resistor for the voltage feedback; therefore, the Imon current with load ∞ is Vout/300MΩ. UM5555 - A7502 User Manual Rev. 3...
Page 6
CAEN Electronic Instrumentation Fig. 2: Male strip header of A7502 Efficiency (%) vs Vout and Temperature (RLoad = 20 MΩ) -60 C° -30 C° 0 C° 30 C° 60 C° 1000 1500 2000 2500 Vout (V) Fig. 3: Efficiency vs Vout and Temperature...
Page 7
Fig. 5: Temperature coefficient vs Vout Uniformity (-60 to 60 C° RLoad = 20 MΩ) 0,60% 0,50% 0,40% 0,30% 0,20% 0,10% 0,00% 1000 1500 2000 2500 Vout (V) Fig. 6: Uniformity of a Lot (ΔVout/Vout) UM5555 - A7502 User Manual Rev. 3...
Page 8
Offset Current vs Vout and Temperature 4,05 3,55 3,05 2,55 -30 C° 2,05 0 C° 1,55 30 C° 60 C° 1,05 0,55 0,05 1000 1500 2000 2500 Vout (V) Fig. 8: Offset current Vs, Vout and Temperature UM5555 – A7502 User Manual Rev. 3...
Page 9
Imon current with load ∞ is Vout/300MΩ Example A7502P: if Iset = 2 V, then Imax out = 90 µA ± 22 µA Example A7502P: if Imon = 1 V, then Iout = 45 µA ± 18 µA UM5555 - A7502 User Manual Rev. 3...
Page 10
RTN ground - shield HV Output Fig. 10: A7502 pins position (bottom view) It is necessary to add a regulation current proportional to the operation voltage; the regulation current I equal to Vout/300 MOhm UM5555 – A7502 User Manual Rev. 3...