Removing An Sfp Optical Port; Installing/Removing Modules; Installing A Module - Siemens RUGGEDCOM MX5000RE Installation Manual

Hide thumbs Also See for RUGGEDCOM MX5000RE:
Table of Contents

Advertisement

RUGGEDCOM MX5000RE
Installation Guide
Section 3.5.2

Removing an SFP Optical Port

To remove an SFP optical port, do the following:
CAUTION!
Electrical hazard – risk of damage to equipment. Make sure all electrostatic energy is dissipated before
performing installing or removing components from the device. An electrostatic discharge (ESD) can
cause serious damage to the component once it is outside the chassis.
1.
Make sure all potential electrostatic build-up has been properly discharged to prevent electrostatic
discharges (ESD). This can be accomplished by wearing an ESD wrist strap or by touching Earth or the
chassis ground.
2.
Disconnect the cable from the port.
3.
Swing the metal bail-latch down and pull the port from the module.
Figure 39: Removing an SFP Optical Port (Typical)
1. SFP Optical Port
4.
Store the port in an ESD-safe bag or other suitable ESD-safe environment, free from moisture and stored at
the proper temperature (-40 to 85 °C or -40 to 185 °F).
5.
Insert a plug in the empty port opening to prevent the ingress of dust and dirt.
Section 3.6

Installing/Removing Modules

The following sections describe how to install and remove modules:
Section 3.6.1, "Installing a Module"
Section 3.6.2, "Removing a Module"
Section 3.6.1

Installing a Module

Upon installing a new module in the device, all the features associated to the module are available in the
operating system. For more information, refer to the ROX II User Guide for the RX5000.