Do you have a question about the Carroll CS3 and is the answer not in the manual?
Questions and answers
Alfred JONES
May 27, 2025
what size mattress is sutable for CS3 bed ?
1 comments:
Mr. Anderson
May 27, 2025
The suitable mattress size for the Invacare Carroll CS3 bed varies, but it must conform to the following dimensions:
- Length: 76 in (1930.4 mm), 80 in (2032 mm), or 84 in (2133.6 mm) - Width: 36 in (914 mm), 39 in (991 mm), or 42 in (1067 mm) - Thickness: 6 in (152 mm)
Each size has a small allowable variation: - Length: Minimum to maximum varies by 1 inch - Width: Minimum to maximum varies by 1 inch - Thickness: Between 5.88 in (149 mm) and 6.12 in (155 mm)
Length extenders, long-term care bed accessory (12 pages)
Summary of Contents for Invacare Carroll CS3
Page 1
*1153410N 00* 02/04/15 This document was released at Pre-Release 00.
Page 2
Invacare® Carroll CS Series™ CS3, CS5, CS7, CS9, CS9FX600 en Beds User Manual This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.
Page 3
All rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted.
Invacare® Carroll CS Series™ 1 General 1.1 Symbols Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. See the information below for definitions of the signal words.
Page 6
General Symbols Used on the CS Bed Recycle this product. Refer to 2.4 Disposal, page 17. 1153410-N~00...
Monitor patient frequently. Read and understand the Continued use of the bed with damaged parts could lead User Manual prior to using the Invacare bed and bed to the bed malfunctioning, causing injury to the user rails. User manuals are available at www.invacare.com and/or caregiver.
Page 8
Fall hazard exists due to incorrect installation of bed rails – Unplug from the outlet before servicing. – To avoid injury, ensure that the Invacare bed rails are – Use this bed only for its intended use as described installed correctly and securely attached to the bed in these instructions.
Page 9
Invacare® Carroll CS Series™ WARNING! DANGER! Risk Of Injury Or Damage Risk Of Death, Injury, Or Damage To avoid injury or damage when operating/moving bed: To avoid serious injury or product damage due to – ALWAYS ensure that the individual utilizing the bed tripping hazards, strangulation hazards, and/or entangled, is positioned properly within the confines of the bed.
Page 10
DANGER! Refer to the Bed Rail Entrapment Risk Notification Risk Of Death, Injury, Or Damage Guide at www.invacare.com for additional safety To avoid bed collapse and resulting injury or damage: information. – The weight limit of the occupant of the CS Bed...
Page 11
– Do not use this bed in Active Treatment “Ether NOT, under any circumstances, cut or remove the Environments.” round grounding prong from any plug used with or for Invacare products. In addition, Invacare has placed RED warning tags on some equipment. DO NOT DANGER! remove these tags.
Page 12
Safety DANGER! WARNING! Risk of Death, Injury, or Damage Risk of Injury or Damage In the event of a power outage, the bed can be powered To avoid injury or damage from malfunctioning by its internal battery. (The internal battery is optional controller or electrocution: –...
This is called its “immunity level.” The higher the immunity level, the – Invacare recommends the use of mattress keepers. greater the protection. At this time, current technology is capable of achieving at least a 20 V/m immunity level, which would provide useful protection from the more common sources of radiated EMI.
Safety 2.3 Electromagnetic Compatibility Information Handheld Portable transceivers (transmittersreceivers with the antenna mounted directly on the transmitting unit. Examples Medical Electrical Equipment needs special precautions include: citizens band (CB) radios, “walkie talkie”, security, fire regarding EMC and needs to be installed and put into service and police transceivers, cellular telephones, and other personal according to the EMC information provided in this manual.
Page 15
Invacare® Carroll CS Series™ Guidance and Manufacturer’s Declaration - Electromagnetic Emissions Emissions Test Electromagnetic Environment Compliance - Guidance RF emissions Class B The CS Bed is suitable for use in all establishments, including domestic CISPR 11 establishments and those directly connected...
Page 16
Safety Guidance and Manufacturer’s Declaration - Electromagnetic Immunity Voltage dips, short interruptions <5 % UT <5 % UT Mains power quality should be and voltage variations on power that of a typical commercial or (>95 % dip in UT) (>95 % dip in UT) supply input lines IEC 61000-4-11 hospital environment.
Page 17
Invacare® Carroll CS Series™ Conducted RF 3 Vrms 3 Vrms Portable and mobile RF communications equipment should be used no closer to any part of the CS Bed, including cables, than the recommended IEC 61000-4-6 150 kHz to 80 MHz separation distance calculated from the equation applicable to the frequency of the transmitter.
Safety Recommended separation distances between portable and mobile RF communications equipment and the CS Bed The CS Bed is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the CS Bed can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the CS Bed as recommended below, according to the maximum output power of the communications equipment.
Invacare® Carroll CS Series™ All models (120 V~ models - CS3, CS5, CS7, CS9, CS9FX600 and 230 3 Technical data V~ models - CS5, CS7, CS9) conform to UL60601-1 and IEC60601-1. Certified to IEC60601-2-38 and IEC60601-1-2 and CAN/CSA C22.2 3.1 Typical Product Parameters No.
Page 22
Technical data Electrical Specifications CS9FX600 Control box mains 120V~ 120V~ or 230V~ 120V~ or 230V~ 120V~ or 230V~ 120V~ voltage Control box input 3.5A max 3.5A max (1.5A max 3.5A max (1.5A max 3.5A max (1.5A max 3.5A max current for 200V~ models) for 230V~ models) for 230V~ models)
Page 23
Invacare® Carroll CS Series™ Safety Features CS9FX600 Protective earth Class I ground Electric shock Type B protection Enclosure protection IPX4 Floor lock not available Optional standard not available optional CPR release on head actuator Built-in battery not available optional back-up (standard with Trendelenburg 24V DC 9.2 Amps)
Page 24
Technical data Dimensions and Weight CS9FX600 Length (overall) 76 in and 80 in CS 84¼ in (2140 mm) Beds 80 in CS Bed with 4 88¼ in (2242 mm) in Extension Length between head and foot ends 76 in CS Bed 78½...
Page 25
Invacare® Carroll CS Series™ CS9FX600 Width with assist rails 39¼ in (997 mm) - 36 in standard deck Width with Thinksoft® positioning devices 36 in Standard 41¼ in (1048 mm) 39 in Wide 44¼ in (1124 mm) 42 in Wide 47¼...
Guide at www.invacare.com for additional safety information. A mattress may not be included with this bed. It is highly recommended that you use an Invacare branded mattress that is designed to conform to the following dimensions: Named Size Minimum Size Maximum Size 76 in (1930.4 mm)
Invacare® Carroll CS Series™ Stand bed upright. 4 Setup 4.1 Unpacking Instructions CAUTION! Risk of Damage To avoid product damage from misuse: – DO NOT cut any trimmed plastic wire ties. – Cut only the untrimmed plastic ties around the wood spacer.
Page 28
Setup Slide off end boxes and remove plastic sleeve. Remove the locking key latch from both sides of the wood spacer at the foot end of the bed. WARNING! Risk of Injury or Damage Bed damage or personal injury may occur if bed is dropped.
Page 29
Invacare® Carroll CS Series™ Remove wood spacer from front end of bed by lifting it off of Cut the untrimmed or green plastic tie holding the knee-foot bed end brackets. panel to the frame. Cut the untrimmed or green tie holding the mattress keepers on Cut the untrimmed or green tie holding the head deck to the either side of the bed.
Page 30
Setup Cut the untrimmed or green ties holding the mattress keepers at 11. Carefully cut the untrimmed or green tie holding the mains cable the end of the bed. bundle. 12. Plug power cord into a properly grounded outlet. 10. Carefully cut the untrimmed or green tie holding the pendant bundle.
Invacare® Carroll CS Series™ 4.2 Installing the Mattress Keeper Rod to the Model CS9FX600 Head and Foot Decks WARNING! Risk of Injury or Damage By securing the mattress in place, the mattress keeper rods prevent unsafe gaps from forming between the bed ends or rails and the mattress.
Page 32
Setup Model CS9FX600 Model CS9FX600 There are two choices for mattress keeper rod insertion. (76 in bed option shown above). All Models Except CS9FX600 1153410-N~00...
Page 33
Invacare® Carroll CS Series™ Mattress keeper rod insertion on 80 in Bed. Fold the mattress keeper around the bed in the rod. The mattress keepers should rest flat on the foot deck and the head All Models Except CS9FX600 deck.
Page 34
Setup 76 in Bed Only - Remove the fasteners on the bed end bracket. 76 in Bed Only - Reinsert the bed end bracket fasteners. 76 in Bed Only - Slide the bed end bracket in the mounting channel. Align the hole in the bracket with the channel hole. 1153410-N~00...
Invacare® Carroll CS Series™ 4.3 Installing the Head and Foot Ends 76 in Bed Only - Tighten the fasteners with two 7/16 in wrenches. Reposition the other three brackets and reapply the ends. Head and foot ends are normally packaged together either in a cardboard box or on a wooden skid separate from the bed.
Page 36
Setup Position Foot End next to the foot board brackets. Hook the board screws into the bracket slots. Position Head End next to the head board bracket. Hook the head post screws in the bracket slots. Guide the key through the small bracket hole. The key is attached to the bed bracket with a lanyard.
Page 37
Invacare® Carroll CS Series™ Turn and lock the key once it is fully inserted. Repeat on the other side, then the opposite bed end, securing both mounting points on each board. Some models only have one connection. Attach the cables from the foot end board to the bed cables (ACP cable and pendant coupling).
Usage 5 Usage 5.1 Pendant Operation DANGER! Risk Of Death, Injury, Or Damage To avoid injury or damage from entanglement with bed components or bed collapse: – Keep all moving parts, including the main frame, mattress deck, and all drive shafts, free of obstruction (i.e.
Invacare® Carroll CS Series™ Raise/Lower Head Alternate Pendants Raise/Lower Knee Raise/Lower Bed Raise/Lower Head and Knee 5.2 Pendant Storage and Location WARNING! Risk of Injury or Damage To avoid injury or damage from electrical shock – Before working on any electrical part, such as the...
Page 40
Usage Place the pendant holster between the top rail bars. Alternatively, use the pendant clip to secure the pendant to bed linen. Slide the pendant into the holster. The pendant can also be attached to the back of either side of the Head end.
Page 41
Invacare® Carroll CS Series™ To move the pendant to the other side of the bed, disconnect the On the other side of the bed, remove the cap from the Y cable main power then unscrew the coupling cap on the pendant cable.
Usage 5.3 Power Cord Storage 5.4 Raise and Lower the Heel Lift Ratchet Disconnect the main power cable from the wall outlet and store the power cord when the bed is not in use. With knee-foot platform adjusted to the highest position, lift the foot panel.
Page 43
Invacare® Carroll CS Series™ The foot section can rest at any of the six pre-set stops. The platform cannot lower past the nearest stop while being adjusted. Slowly lower the platform to engage the nearest stop. To reset the ratchet mechanism, raise the platform to the highest level then lower the platform in one motion.
Usage 5.5 Foot Pad Lock Mechanism 5.6 Bed Steer Mechanism For CS3 Model Only CAUTION! Risk of Damage Moving the bed while the floor lock, caster lock, or foot pad is engaged may DAMAGE the bed. To avoid: – DO NOT move the bed unless the floor lock, caster lock, or foot pad is disengaged (unlocked).
Page 45
Invacare® Carroll CS Series™ With the locking wheel tab facing outward, flip the steer mechanism. When engaged the bed will steer easily. 1153410-N~00...
DANGER! Monitor patient frequently. Read and understand the Risk Of Death or Injury User Manual prior to using the Invacare bed and bed An increased risk of patient entrapment may occur over rails. User manuals are available at www.invacare.com time due to mattress compression.
Page 47
CPR release feature. trapeze. – DO NOT install an 84 Inch CS Bed kit on a bed that – Use only Invacare trapeze systems designed specially is equipped with the Trendelenburg and Reverse for the CS bed: Standard Trapeze (1153385) or Heavy Trendelenburg feature.
Options If necessary, the head and foot end board position can be Model Description adjusted in order to meet FDA guidelines. Refer to the IHCSBEK 4 Inch Extension Kit section titled, “Install the Mattress Keeper Rod to the Head and Foot Decks” for detailed instructions on adjusting the IHCSDB Drainage Bag Holder end board bracket location.
Invacare® Carroll CS Series™ 6.3 Optional Drainage Bag Holder 6.5 Optional Attendant Control Panel Operation 4 Function Pendant 6.4 Optional Touch-up Paint Using the integrated Nurse Call Feature Sherwin-Williams® Locate call cord cable at the head of the bed along with the 5A-58147 00(A) power cord.
Page 50
In the event of a power failure or an issue occurs within the electronic system of your Invacare bed, the nurse call button will be activated, and will not be reset until the electronic system is running properly. Remove the nurse call plug to disable nurse call signal until service is preformed.
Page 51
Invacare® Carroll CS Series™ Alternate Pendants Attendant Control Panel Lockout All functionality is the same on the alternate pendants except where noted. 1153410-N~00...
Options 6.6 Optional Trendelenburg and Reverse Trendelenburg Attendant Control Panel CAUTION! Risk of Damage Use of Trendelenburg or Reverse Trendelenburg feature may not be appropriate for certain patients. – Trendelenburg and Reverse Trendelenburg should only be used on the advice of a medical practitioner. –...
Invacare® Carroll CS Series™ 6.7 Optional Pendant HI/LO Lock Out When in the “OFF” position, the HI/LO function on the pendant will NOT operate. When in the “ON” position, all pendant functions will operate normally. The head function and knee-foot function on the pendant remains operational whether the lock out is activated or deactivated.
Options 6.8 Optional Cardiopulmonary Resuscitation (CPR) Release WARNING! Risk of Injury or Damage Activation of the CPR release may cause attendant or resident injury. To avoid: – Use the CPR release only for emergency situations. This function will rapidly bring the head deck to a flat position.
Invacare® Carroll CS Series™ 6.9 Optional 39 Inch and 42 Inch Wide Decks Grip the CPR handle (at the foot end of bed ). The following bed options are not compatible with the 39 Foot end not shown for clarity.
Page 56
Options The CS9FX600 has eight adjustable deck wings which can be adjusted to 36 in, 39 in or 42 in. The locations of the wings and adjustment knobs are shown in the figure below. Opposite side is the same as labeled side. 1153410-N~00...
Page 57
Invacare® Carroll CS Series™ 36 inch Width 39 inch Width 42 inch Width Side View Side View Side View Top Bed Deck View Top Bed Deck View Top Bed Deck View Loosen the knob A securing the adjustable deck wing B.
Options Adjust the head board width. Refer to 6.10.2 Adjusting the Head Firmly grasp one of the board wings A. Board Width for CS9FX600, page 57. While holding the board wing, remove the knobs B securing Repeat steps 1 to 6 for each section until they are all adjusted that wings to the center section C.
Invacare® Carroll CS Series™ 7 Maintenance 7.1 Cleaning • Unplug product before washing. Inspect rail latches. Ensure that all rails engage and lock as Make sure all electrical parts (motors, control box and pendant) specified. • are not damaged and that all connection ports are plugged. DO Inspect rails for wear and damage and replace as required.
Floor lock not functioning. Floor lock is stuck in one position. Contact Invacare Continuing Care Service Department 1-800-668-2337. Bed is not level Hi/Lo actuators are unevenly Bed deck is not parallel with floor...
Page 61
Invacare® Carroll CS Series™ Effect Possible cause Verification Corrective action Actuator not working. System Fault Flashing LEDs on ACP, Bed To Reset - hold the pendant function will not operate. The bed up and bed down buttons Needs Reset control box may beep when for 5+ seconds.
Page 62
Troubleshooting Effect Possible cause Verification Corrective action Faulty actuator. Disconnect power supply, swap Contact Invacare Continuing cable from unresponsive actuator Care Service Department with a functional actuator. 1-800-668-2337. Reconnect power and test functions. Faulty actuator will not work regardless of the connection port.
This warranty is extended only to the original purchaser who satisfactory warranty service, please write directly to ICCI at the purchases this product when new and unused from Invacare address on the back cover, provide dealer's name, address, and the Continuing Care, Inc (ICCI) or a dealer.
Page 64
Warranty OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER, SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PERSUANT TO THE TERMS CONTAINED HEREIN. THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN.
Page 65
Invacare Continuing Care, Inc. A subsidiary of Invacare Corporation. www.invacare-cc.com Invacare Continuing Care, Inc. USA and Canada: Designed by Invacare Corporation Invacare Australia Pty. Ltd. One Invacare Way Manufactured in Mexico for Invacare 1 Lenton Place Corporation Elyria, Ohio USA North Rocks NSW 2151 44036–2125...
Need help?
Do you have a question about the Carroll CS3 and is the answer not in the manual?
Questions and answers
what size mattress is sutable for CS3 bed ?
The suitable mattress size for the Invacare Carroll CS3 bed varies, but it must conform to the following dimensions:
- Length: 76 in (1930.4 mm), 80 in (2032 mm), or 84 in (2133.6 mm)
- Width: 36 in (914 mm), 39 in (991 mm), or 42 in (1067 mm)
- Thickness: 6 in (152 mm)
Each size has a small allowable variation:
- Length: Minimum to maximum varies by 1 inch
- Width: Minimum to maximum varies by 1 inch
- Thickness: Between 5.88 in (149 mm) and 6.12 in (155 mm)
This answer is automatically generated