Donaldson Radialseal™ Air Cleaner - Walker T23 Operator's Manual

Table of Contents

Advertisement

Maintenance Instructions
Donaldson Radialseal™ Air Cleaner
A remote mounted Donaldson Radialseal™ air
cleaner provides the air filtering function. The paper
filter element slides over an outlet tube inside the air
cleaner canister with radial sealing action, reducing
the possibility of dust leaks due to improper filter
installation. Intake design, internal baffling, and a
dust ejection valve provide dust separation and
auto matic precleaning action. Daily or frequent ser-
vicing of the air cleaner is not required. Use the air
filter re striction gauge on the air cleaner outlet to
indicate when the air filter needs servicing -- a yellow
indicator will show when the filter is overly restricting
airflow into the engine.
IMPORTANT: Use only Donaldson air filter ele-
ments for replacement (Donaldson P822686 or
Walker 5090-1). Aftermarket filters may not seal
properly or filter efficiently.
Cover
Cover
Latch
Dust Ejection
Air Cleaner Components
(Shown with Cover Being Removed)
IMPORTANT: The Donaldson air cleaner uses a dry
paper-type air filter element. NEVER apply oil to the
paper element.
Canister
Primary
Filter Element
Valve
Push Button to Reset
Indicator After Service
Restriction Gauge
Air Filter Restriction Gauge Location
Inspect the paper element after every 100 hours of
service and replace the element and safety filter
yearly (or when dirty or damaged). More frequent
replacement may be required when operating in ex-
tremely dusty con ditions as indicated by the air filter
restriction gauge. Ser vice the air cleaner as fol-
lows:
1.
Release the top and bottom cover latches and
remove the air cleaner cover. Wash the cover
and dust ejection valve. Check that these com-
ponents are in good condition. The dust ejec-
tion valve is subject to wear and deterioration
and should be inspected carefully and replaced
yearly or when damaged. The lips of the valve
should close and fit togeth er; any cracks, defor-
mation, or wear in the valve is cause for re-
placement.
2.
Remove the filter element by pulling it out of the
canister. There will be some initial resistance
as the filter seal breaks loose and slides off of
the outlet tube. Gently move the end of the
filter up and down and side to side or twist to
loosen the seal. Use gentle action to minimize
the amount of dust dislodged as the filter is re-
moved.
3.
Discard the filter element if excessive air flow
restriction has been indicated by the air filter
restriction gauge and proceed to Step 6. Clean
the filter element by gently tapping on a flat,
hard surface. If excessive restriction still exists
after cleaning the element, it should be re-
placed.
CLEANING
Air Filter
63

Advertisement

Table of Contents
loading

Table of Contents