Checking Oil Level
Oil level should be checked prior to each use or
at least every 8 hours of operation. Keep oil level
maintained.
1. Make sure generator is on a level surface.
2. Loosen the side maintenance cover screws and
remove the side maintenance cover.
3. Clean area around oil fill and remove oil fill cap.
4. Verify oil is at the point of overflowing at oil fill
opening.
5. Replace and tighten oil fill cap.
6. Reinstall the side maintenance cover and hand
tighten the cover screws.
Adding Engine Oil
1. Make sure generator is on a level surface.
2. Repeat steps 2 through 4 to check oil level as
described in Checking Oil Level.
3. If needed, slowly pour oil into oil fill opening to the
point of overflowing at oil fill.
4. Replace and tighten oil fill cap.
5. Reinstall the side maintenance cover and hand
tighten the cover screws.
18
Changing Engine Oil
If you are using your generator under extremely dirty or
dusty conditions, or in extremely hot weather, change
the oil more often.
CAUTION Avoid prolonged or repeated skin
contact with used motor oil.
• Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
• Thoroughly wash exposed areas with soap and water.
   K EEP OUT OF REACH OF CHILDREN. 
DON'T POLLUTE. CONSERVE
RESOURCES. RETURN USED OIL TO
COLLECTION CENTERS.
Change the oil while the engine is still warm from
running, as follows:
1. Make sure generator is on a level surface.
2. Loosen the side maintenance cover screws and
remove the side maintenance cover.
3. Clean area around oil fill and remove oil fill cap.
4. Tip your generator to drain oil from oil fill into a
suitable container making sure you tip your unit
toward the oil filler neck. When crankcase is
empty, return generator to upright position.
5. Slowly pour oil (about 20 oz.) into oil fill opening
to the point of overflowing at oil fill cap. DO NOT
overfill.
6. Reinstall oil fill cap. Finger tighten cap securely.
7. Wipe up any spilled oil.
8. Reinstall the side maintenance cover and hand
tighten the cover screws.