Issue Date:
Ref. No:
Subject:
Information Only
Applicability:
XTi Amplifiers: below serial number 8001377031
CDi / DSi Amplifiers: below serial number 8001377296
Conditions:
Erratic volume, no audio or intermittent audio on the output. The Signal LED may stay lit even
without audio output.
Part Description:
138911-4; XTi Display board "New"
138912-4; CDi/DSi Display board "New"
Procedure:
When an XTI, CDI, or DSi amplifier is returned with a complaint of changing volume level or
intermittent output audio, replace the display board with a 13891X-4 or greater revision.
Root Cause:
Damage to the solder-in end of the ribbon cable during manufacture. The new connector, (see
Figure 1 above, picture shown is of the CDi/DSi display board), is more robust and not easily
damaged. In some instances topside solder on R73/R74 potentiometers can cause the erratic
volume. In either case the display board with 13891X-4 or greater revision will resolve the
issue.
请到http://bbs.bjjdwx.com
Tech Note
Crown Technical Support
PO Box 1000 Elkhart IN 46515
Ph 800-342-6939/574-294-8200
Fax 574-294-8301
16-Aug-07
Tech Note# 190
XTi/CDi/DSi Display boards
Apply to Service Units Only