SCC MAM – 890 Operation Manual page 10

Compressor controller
Table of Contents

Advertisement

SEQ DELAY TIME
OIL FILTER RST
O/A FILTER RST
AIR FILTER RST
LUBE RESET
GREASE RESET
BELT RESET
OIL FILTER SET
O/A FILTER SET
AIR FILTER SET
LUBE SET
GREASE SET
BELT SET
Language select
User password modification
04.08.2017
In SEQ mode, when master sends two commands continuously, second command
200S
signal delays for this set data
Record total running time of OIL filter. If changing new oil filter, the data should
0000H
be reset by manual operation.
Record total running time of O/A separator. If changing new O/A separator, the
0000H
data should be reset by manual operation.
Record total running time of AIR filter. If changing new AIR filter, the data should
0000H
be reset by manual operation.
Record total running time of LUBE. If changing lubricate, the data should be reset
0000H
by manual operation.
Record total running time of GREASE. If changing new grease, the data should be
0000H
reset by manual operation.
Record total running time of BELT. If changing new belt, the data should be reset
0000H
by manual operation.
1. Alarm prompt when total running time of oil filter is above the set data.
0500H
2. Set this data to "0000", alarm function for oil filter running time is not
activated
1. Alarm prompt when total running time of O/A separator is above the set data.
3000H
2. Set this data to "0000", alarm function for O/A separator running time is not
activated
1. Alarm prompt when total running time of air filter is above the set data.
0500H
2. Set this data to "0000", alarm function for air filter running time is not
activated
1. Alarm prompt when total running time of lubricant is above the set data.
0500H
2. Set this data to "0000", alarm function for lubricant running time is not
activated.
1. Alarm prompt when total running time of grease is above the set data.
3000H
2. Set this data to "0", alarm function for grease running time is not activated
1. Alarm prompt when total running time of belt is above the set data.
3000H
2. Set this data to "0", alarm function for grease running time is not activated
English
Change the display language.
User could modify the user password by old user password or factory password
****
Operation Manual MAM - 890 V1.0
-
10 -

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for SCC MAM – 890

Table of Contents