BATTERY INSTALLATION

The RIT-PAK III Portable Air Supply requires two (2) AA batteries in the remote gauge
console for operation of the air cylinder volume LED DISPLAY indicator lights. The batter-
ies should be replaced only by a trained maintenance technician in a clean area known
to be nonflammable.
Install or replace the batteries as follows:
1.
Locate the remote gauge console.
2.
Using a Phillips driver, remove both battery caps holding. See FIGURE 5.
REMOVE
BOTH CAPS
FIGURE 5
3.
I f p r e v i o u s l y i n s t a l l e d , s l i d e t h e t w o b a t t e r i e s o u t o f t h e b a t t e r y
compartments.
4. For best results, replace batteries only with a pair of the following 1.5 volt
AA batteries:
Eveready
Energizer Alkaline EN91
1
Eveready Energizer Alkaline E91.
Duracell
Alkaline MN1500
2
Duracell Alkaline MX1500
Duracell Alkaline PC1500
Be sure batteries are properly oriented in battery compartments with the
"+" end and the "–" end of each as shown in FIGURE 6.
5. The battery covers must be installed so that they are water tight after replace-
ment. Clean the inside edge of each battery compartment and seal around
the outside of the cover by wiping with a clean damp cloth to remove any dirt
or foreign matter which might prevent a proper seal. Check cover gasket for
tears or cuts. If damage is found, remove equipment from service and tag for
repair by authorized personnel.
6.
When cover is placed in position and the batteries are properly installed, all
lights in the LED DISPLAY will light for approximately twenty (20) seconds
to verify operation.
7. Thread the battery cover screws in until the edge of each battery cover is
touching the face of the battery compartment. Tighten the screw HAND TIGHT
only. DO NOT OVERTIGHTEN. Perform the REGULAR OPERATIONAL IN-
SPECTION to verify proper operation of the LED DISPLAY.
Energizer is a registered trademark of Eveready Battery Company, Inc., St. Louis, MO.
1
Duracell is a registered trademark of The Procter & Gamble Company, Cincinnati, OH.
2
"+" END
OUT
FIGURE 6
Page 8 of 36
REGULARLY INSPECT THIS EQUIPMENT,
INCLUDING THE GAUGE CONSOLE
AND LED DISPLAY, AS DESCRIBED IN
THIS INSTRUCTION AND CORRECT ANY
DAMAGE FOUND. DO NOT SUBSTITUTE
ANY PARTS OR COMPONENTS. USE ONLY
THE BATTERIES AS SPECIFIED IN THIS
INSTRUCTION. THE FAILURE TO CORRECT
ANY DAMAGE, THE INSTALLATION
O F I N C O R R E C T B AT T E R I E S , O R
"–" END
THE SUBSTITUTION OF ANY OTHER
COMPONENTS MAY LEAD TO A FIRE OR
OUT
AN EXPLOSION WHICH COULD RESULT IN
SERIOUS INJURY OR DEATH.
BATTERIES MUST ONLY BE CHANGED IN
AN AREA KNOWN TO BE NONFLAMMABLE.
C H A N G I N G T H E B AT T E R I E S I N A
FLAMMABLE ATMOSPHERE MAY CAUSE
AN IGNITION WHICH COULD RESULT IN
SERIOUS INJURY OR DEATH.
USE BATTERIES ONLY FROM THE LIST
PROVIDED, DO NOT MIX OLD BATTERIES
WITH UNUSED BATTERIES, AND DO
NOT MIX BATTERIES FROM DIFFERENT
MANUFACTURERS.
WARNING
WARNING
CAUTION
P/N 595225-01 Rev C 4/12