Dometic RM5310 Operating Manual page 18

5 series absorber refrigerator
Hide thumbs Also See for RM5310:
Table of Contents

Advertisement

Available languages

Available languages

Operating the refrigerator
7.2
Switching on the refrigerator (RM5310, RM5330,
RM5380)
Operating with AC power supply
➤ Switch the refrigerator on by turning the power selection button to the
position.
Operating with DC power supply
➤ Switch the refrigerator on by turning the power selection button to the
position.
Gas operation (fig. 6, page 3)
!
WARNING! Fire hazard!
Never operate the refrigerator with gas at petrol stations.
I
NOTE
When operating with LPG, the burner must be cleaned frequently
(two or three times a year).
➤ Make sure that the gas supply is turned on.
➤ Turn the power selector switch to the
➤ Turn the temperature control to the maximum level (A).
➤ Press in the temperature regulator and hold it down.
➤ Press in the battery igniter as well and hold it down (B).
✓ The burner is ignited automatically. The needle of the pilot light moves to the
green zone once the burner has ignited (C).
➤ Press and hold down the temperature regulator for another 15 seconds.
18
position.