S ection 5 ·
Instal lation
5.5

Pin assignment

RJ45 socket
Left: Pin 1
Right: Pin 8
PIN
Telefon
Analog
1
2
3
4
b= minus
5
a= plus
6
7
8
PIN
Ethernet
Name
1
TPTX-
2
TPTX+
3
TPTX+
4
5
6
TPTX-
7
8
PIN
Powador-go
Name
1
+12V...24V
2
+12V...24V
3
+12V...24V
4
b= plus
5
a= minus
6
GND
7
GND
8
GND
5.6

Jumper switch (M/L/XL only)

The Powador-proLOG M/L/XL has three jumper switches
located on the circuit board. You can set the following operat-
ing modes:
Page 16 16
ISDN
STA / (B2)
SRA / (B1)
SRB / (A1)
STB / (A2)
Funktion
Transmit Data
Transmit Data
Transmit Data
Transmit Data
Funktion
Versorgung
Versorgung
Alarmausgang
Datenleitung
Datenleitung
Alarmausgang
Versorgung
Versorgung
OPTO <-> BEEPER
You can set the jumper to OPTO or BEEPER.
OPTO: Only the D0 output is activated.
BEEPER: The D0 output and the internal horn are activated.
N OT E
The BEEPER should only be active when the D0 output is
used as an alarm output.
Powador <-> Powador+Powador-go
You can set the jumper to Powador or Powador+Powador-go.
Powador: The RS485 signal is only present at the "B A
RS485" terminal strip. Only the Powador invert-
ers can be operated.
I M P O RTA N T
If only inverters are connected (without current sensors),
make sure the jumper is set to "Powador". Otherwise,
you cannot communicate with the inverters.
Powador+Powador-go:
The RS485 signal is present at the "B A RS485" terminal strip
and at the "Powador-go" RJ45 sockets. The current sensors
and the inverters can be operated together.
The RS485 signal is internally bridged from the RJ45
"Powador-go" socket to the "B A RS485" terminal strip
using the "Powador+Powador-go" jumper setting.
24 V internal <-> 24 V external
You can set the jumper to INTERNAL or EXTERNAL. This
jumper affects the front socket of the "24 V external" connec-
tion.
INTERNAL: The Powador-go units draw their power from
the internal power supply of the Powador-pro-
LOG.
EXTERNAL: An external voltage supply for the Powador-go
units can be connected to the "24 V external"
terminal strip.
Reset
Use the reset button to
restart the Powador-proLOG.
Operating Instructions Powador-proLOG_EN