Service flow rate 1"
Backwash flow rate 1" (includes bypass)
Service Flow Rate 1.25" (includes meter)
Service Flow Rate 1.25" (includes meter & bypass)
Backwash flow rate 1.25"
Backwash flow rate 1.25" (includes bypass)
Minimum/Maximum Operating Pressures
Minimum/Maximum Operating Temperatures
AC Adapter:
Supply Voltage
Supply Frequency
Output Voltage
Output Current
Regenerant Refill Rate
Injectors
Drain Line Flow Controls
Inlet/outlet Fitting Options
Distributor Tube Opening WS1HR&HS Valve
Distributor Tube Opening WS1.25HR&HS Valve
Tank Thread
Control Valve Weight
PC Board Memory
Compatible with regenerants/chemicals
wd-15
27 gpm (102.2 lpm) @ 15 psig (103 kPa) drop
27 gpm (102.2 lpm) @ 25 psig (172) kPa) drop
34 gpm (128.7 lpm) @15 psig (103 kPa) drop
32 gpm (121.1lpm) @ 15 psig (103 kPa) drop
32 gpm (121.1 lpm) @25 psig (172 kPa) drop
30 gpm 9113.5 lpm) @ 25 psig 9172 kPa) drop
20 psi (138 kPa) - 125 psi (862 kPa)
40°F (4°C) - 110°F (43°C)
U.S.
120 V AC
60 Hz
12 V AC
500 mA
0.5 gpm (1.9 lpm)
See Injector Graphs
See Table 7
(a) 1" NPT elbow which has a unique drill out
feature to allow a 1/4" NPT connection to the
inlet and/or outlet
(b) 3/4" &1" PVC solvent weld fitting
(c) 1" straight brass sweat fitting
(d) 3/4" straight brass sweat fitting
(e) 1" plastic male NPT fitting
(f) 1 1/4" plastic male NPT fitting
(g) 1" plastic make BSPT fitting
(h) 1 1/4" plastic make BSPT fitting
1.05" outside diameter (3/4" NPS)
1.32" outside diameter (3/4" NPS)
32 mm outside diameter
2 1/2" - 8 NPSM
4.5 lbs.
2.0 kg
Nonvolatile EEPROM
(electrically erasable programmable ready only
memory)
Sodium chloride, potassium chloride, potassium
permanganate, sodium bisulfite, chlorine and
chloramines.
INTERNATIONAL
230 V AC
50 Hz
12 V AC
500 mA