Alignments - Philips VAD8031 Service Manual

Dvd video recorder
Table of Contents

Advertisement

8. Alignments

In case of a change of DVD-M or PWB a readjustment is
necessary to align the OPU and PWB to each other.
8.1
Necessary Tools
Personal computer with Windows 2000
TM
XP
USB to ATAPI adapter, (standard computer equippment)
see figure 8-1.
"Applicator software" (v2.85.00).
Figure 8-1 , USB to ATAPI adapter
8.2
Adjustment Procedure
Connect the basic engine to the USB to ATAPI adapter
Power on the adapter
Connect the USB connector of the adapter to the PC.
Note that the USB bus supports "Hot Plugging". That
means the computer can already be switched on.
Alternatively you can connect the basic engine directly to
the IDE bus of a computer. In this case the adapter is not
necessary but the PC has to be switched off and must be
started up in order to detect the new drive on the IDE bus.
Call up the applicator software, see figure 8-2
Set the timeout to 50 seconds, see figure 8-3
Run the "Adjust Laser Control" command, see figure 8-4.
The "Status" indicator in the left section of the window has
to become green after successful adjustment.
After repairing the drive it should be tested at least with the
following discs:
1.
LVP 12.01 (710409991731) test layer change on track 28
->31
2. DVD+R disc. Use Disc type Ricoh 4X DVD+R
-
Record 1 minute
-
press stop
-
Open / close
-
Play back recorded track
3.
CD-RW low reflection audio disc. (7104 099 96581)
Alignments
TM
or Windows
VAD 8031
Figure 8-2 , Applicator Software
Figure 8-3 , Set Timeout
Figure 8-4 , Run Adjust Laser Control
8.
EN 31