Philips VAD8031 Service Manual page 8

Dvd video recorder
Table of Contents

Advertisement

EN 8
5.
VAD 8031
5. Diagnostic Software
5.1
General
Please refer to the service manual of the recorder for a
description of the complete Diagnostics Software. In this
manual only drive specific error codes are explained.
5.2
Error Codes
With DSW command 910 (Digital Board Chrysalis) the set
software can retrieve an overview of all occurred engine errors.
5.2.1
Momentary Errors
Byte 0: latest error:
Overview of the BE error codes.
error
error
code
0x00
no_error
0x01
illegal_command_error
0x02
illegal_parameter_error
0x03
command_timeout_error
0x04
sledge_home_error
0x05
sledge_calibration_error
0x06
sledge_unstable_error
0x07
speed_timeout_error
0x08
speed_window_error
0x09
focus_timeout_error
0x0A
focus_retries_error
0x0B
focus_agc_error
0x0C
radial_timeout_error
0x0D
radial_retries_error
0x0E
radial_agc_error
0x0F
radial_init_error
0x10
hf_pll_error
Diagnostic Software
meaning
No error has occurred
Command not allowed in this
state or unknown command
Parameter(s) not valid for
this command
The
maximum
execution
time for the command has
exceeded
The sledge could not be
moved home
An error occurred during cal-
ibration of the sledge
The sledge detected unsta-
ble control
Spindle motor could not
reach its target speed within
timeout
Measured spinning speed is
not within expected window
Focus could not be achieved
within the timeout
The amount of focus retries
expired
The focus agc results are out
of range
Servo didn't get on track
within the timeout
Servo didn't get on track after
several retries
The radial agc results are out
of range
Unreliable signal scaling af-
ter the radial initialisation
HF-decoder pll could not lock
to HF signal
0x11
wobble_pll_error
0x12
subcode_timeout_error
0x13
subcode_notfound_error
0x14
header_timeout_error
0x15
adip_timeout_error
0x16
adip_window_error
0x17
adip_sync_error
0x18
atip_timeout_error
0x19
atip_notfound_error
0x1A
atip_window_error
0x1B
atip_sync_error
0x1C
tray_error
0x1D
seek_error
0x1E
no_hf_present_error
0x1F
record_error
0x20
illegal_stopaddress_error
0x21
no_disc_error
0x22
not_initialised_error
0x23
illegal_medium_error
0x24
cd_frequency_error
0x25
dvd_frequency_error
0x26
re-
served(non_existing_bca_
error)
0x27
reserved(bca_read_error) An error occurred during
0x28
selftest_error
0x29
i2c_error
0x2A
laser_pll_error
0x2B
laser_forward_sense_erro
r
0x2C
jitter_optimisation_error
0x2D
tilt_calibration_error
0x2E
reserved
Wobble pll could not lock to
wobble signal
Subcode information could
not be read
Requested
subcode
item
could not be found
Header information could not
be read
Adip information could not be
read
Adip address was not within
expected window
No adip sync was detected
Atip information could not be
read
Requested atip item could
not be found
Atip address was not within
expected window
No atip sync was detected
Tray could not be closed or
opened within the timeout
The requested seek couldn't
be performed within the time-
out
Attempt to read from a blank
area
An error occurred during the
recording
The requested stopaddress
with modify-stop-address is
not valid
No disc is detected
The system is not initialised
(e.g. seek on unknown disc-
type)
BE detected an unsupported
medium during disc recogni-
tion
Measured HF frequency is
not within CD frequency
range
Measured HF frequency is
not within DVD frequency
range
Attempt to read non-existing
bca information
reading of bca information
An error occurred during the
self-test of the BE
The I2C interface does not
operate
Laser control pll did not lock
or lost lock on write clock
Forward sense value didn't
change with changing laser
power
An error occurred during op-
timisation of the jitter
An error occurred during cal-
ibration of the tilt frame

Advertisement

Table of Contents
loading

Table of Contents