Cedes ObjectC 100 I/O Programmer's Manual page 28

Multiple proximity switch systems for object recognition
Table of Contents

Advertisement

ObjectC 100
Figure 14: Example of pallets being sorted according to height:
Zones can be defined as overlapping and zones may contain as few as one beam or as many as all beams
(Figure 15). A zone is defined by specifying two beams, a low and a high beam, e.g. zone 3 in the left side of
Figure 15 is defined by z3L = 13 and z3H = 19.
The ObjectC
100
I/O controller has 4 digital outputs, one representing the status for each of the 4 zones.
-
-
ObjectC°100°CAN and RS485 do not offer zone monitoring, but beam information can be determined using the
communication telegram "Get zone status (40 [28 Hex]".
28
Goods G1 to Zone Z1
Goods G2 to Zone Z3
Goods G3 to Zone Z4
Table 52: Example for an evaluation for a palet transport storage system
Zone Status
Z4
Z3
Z2
0
0
0
0
0
0
0
0
1
0
1
1
1
1
1
http://csa.cedes.com/
B
Blanked beams
CZ
Carrier zone
Good height
Z1
No goods
0
(or carrier only)
1
Goods with height 1
1
Goods with height 2
1
Goods with height 3
1
Goods with height 4
Programmer's Guide