Periodic Mode - Cedes ObjectC 100 I/O Programmer's Manual

Multiple proximity switch systems for object recognition
Table of Contents

Advertisement

ObjectC 100
Table 41: Limitation of data transfer
Parameter
82 [52 Hex]
Limitation of data transfer
x
t
= n
13.1 ms
d
An Event (E) triggers a measurement, but it is performed in a delay of the time t
certain size and speed is recognized (Figure 3 G1, G2 and G4).
2.3.8.

Periodic mode

Periodic mode is activated with these parameters.
Table 42: Parameters for periodic mode
Parameter
75 [4B Hex]
Periodic measuring
77 [4D Hex]
Event measuring
After the periodic time of t = n x 13.1 ms, the response telegrams "State sector X-axis (64 [40 Hex])" and/or
"This command delays the
State sector Y-axis (66 [42 Hex])" are transmitted. The periodic mode lends itself to collect the length and/or
profile of an object.
Figure 4: The periodic mode triggers measurements in time intervals of Tn = n x 13.1
ms, T1, T2, T3, T4, T5 etc. ). It lends itself for applications to determine the length or
the profile of goods (G1).
For object G1, according to Figure 4, passing the light curtain with a constant speed, the length is calculated as:
18
t
Delay time [ms]
d
n
Value of parameter 82 [52 Hex]
Figure 3: The goods trigger events (E) but the measurements are performed with a
delay (M)
response times according Operation manual (Part No. 104 906 Chapter 11.2)
Value n
Description
0
Telegram at every event
1-255
delay of n times 13.1 ms
Value n
Description
Periodic mode active with time
3-255
constant tp
0
Event mode inactive
http://csa.cedes.com/
Programmer's Guide
. Therefore only an object of a
d
© CEDES Safety & Automation AG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Objectc 100 rs485Objectc 100 can

Table of Contents