Editing The Configuration Parameters - Pioneer DRM-6NX Operating Instructions Manual

Network cache changer drm-6nx operating instructions
Hide thumbs Also See for DRM-6NX:
Table of Contents

Advertisement

Appendix A : Parameter List

Editing the Configuration Parameters

Web Browser
If your network supports TCP/IP, you may display and
edit the DRM-6NX parameter list using any standard
Web browser. Note that you must first assign a valid
Internet address as described in " Assigning an Internet
Address " on page 14.
To access the DRM-6NX Home Page from your Web
browser, simply enter the URL of the DRM-6NX, (i.e.
the name or Internet address, in the location/
address field)
Example:
http://172.16.253.80
Text Editor
The configuration settings for the DRM-6NX are stored
in the config.ini file located in the System/Server
Properties folder. You may use your preferred text
editor to make updates to the file.
Submit the new settings to the DRM-6NX by saving the
file. To activate the new settings, it is necessary to restart
the DRM-6NX. Set the Restart parameter to Yes.
Configuration Settings
The DRM-6NX configuration settings are stored in the
config.ini file located in the System/ServerProperties
folder.
Example:
; Parameter List, V5.00
[Server]
HardwareAddress
Date
Time
FactoryDefaults
Restart
TimeZone
TimeSyncSource
ServerPassword
Cache
[SCSI]
SCSITermination
JukeBoxLockTime
Disconnect_Reselect
BusMode
44
<DRB1239>
= 00:40:cc:24:c0:0c
= 98-11-02
= 08:54:37
= no
= no
= UTC
= None
= ********
= mirror
= on
= 0
= on
= Asynchronous
[IP]
InternetAddress
DefaultRouter
NetMask
BOOTPEnable
DHCPEnable
RARPEnable
...
Access Control Parameters
The DRM-6NX access control parameters are stored in
separate text files for each shared resource. These text
files are located in the System/VolumeProperties folder.
NOTE:
7 The text files cannot be used for setting up access rights to
NetWare. Instead, use NWAdmin or Filer
Example:
...
; Explanations:
;
[W] - Writable
;
[R] - Read-only
--- Identification ---
[R] Volume name = Root
[R] Volume label = Root
[R] Volume serialnumber = 00000001
[W] Volume description =
...
; Access rights
...
--- Windows Sharing ---
...
File
= /
Share name
Comment
AccessRight
Read-Only Password
Full Access Password =
[END]
NOTES:
7 When editing the file, be sure that the equal sign and the parameter
value is separated by a space.
7 Do not remove the [END] marker from the file.
= 172.16.253.80
= 172disc.16.1.1
= 255.255.0.0
= yes
= yes
= yes
= Root
=
= Full-Server-Password
=