Amprobe ACD-14-PRO User Manual page 19

Dual display 600 a trms clamp multimeters
Table of Contents

Advertisement

Available languages

Available languages

DC μA
Range
200.0 μA, 2000 μA
Temperature
Range
- 40.0 °C to 99.9 °C
100 °C to 400 °C
-40.0 °F to 99.9 °F
100 °F to 752 °F
1) K-type thermocouple accuracy tolerances not included.
2) To meet stated accuracy, the thermocouple probe connector plug and
Meter must be stabilized at the same temperature. When measuring
below 0 °C (32 °F) ensure the Meter is warmed up at minimum of 20
minutes with the probe connector plug connected before making
temperature measurements.
Precise Low Current AC (Amp-Tip)
Range
60.00 A
Frequency: 50 Hz to 60 Hz
1) Induced error from adjacent current-carrying conductor: < 0.06 A/A
2) Induced error from AC V measurement < 0.60A /kV @ 50/60 Hz
3) Add 10 LSD to the specified accuracy @ < 6 A
4) Unspecified at currents < 0.2A if function continuity
(NCV) is selected in the lower display.
AC Current
Range
5)
60.00 A
, 600.0 A
5)
60.00 A
, 600.0 A
1) Induced error from adjacent current-carrying conductor: < 0.06 A/A
2) Induced error from AC V measurement < 0.60A /kV @ 50/60 Hz
3) Specified accuracy is for measurements made at the jaw center. When
the conductor is not positioned at the jaw center, add 2% to specified
accuracy for position errors
4) Unspecified at currents < 0.2A if function continuity
(NCV) is selected in the lower display.
5) Add 10 LSD to specified accuracy @ < 6 A
PEAK-rms (for AC A function)
Response: 80 ms to > 90 %
Accuracy
± (1.0 % + 5 LSD)
Accuracy
±(1% + 0.8 °C)
±(1% + 1 °C)
±(1% + 1.5 °F)
±(1% + 2 °F)
1) 2) 3) 4)
Accuracy
± (1.5 % + 5 LSD)
1) 2) 3) 4)
Accuracy
± (1.8 % + 5 LSD) @ 50 Hz to <100 Hz
± (2.0 % + 5 LSD) @ 100 Hz to 400 Hz
15
Burden Voltage
3.5 mV/μA
or EF-Detection
or EF-Detection