Preparing for Operation
Example of 3-wire Sequence Mode
Stop
switch
(contact b)
Example of Operation
Forward rotation
Motor operation
Reverse rotation
Run command
Stop command
Forward/Reverse
rotation command
n02
Operation Mode Selection
Setting range
This constant is used to specify whether the Inverter is to be operated with a Digital
Operator or external signals.
Value
Run command
0
Digital Operator
1
Control terminal
2
Digital Operator
3
Control terminal
4
Digital Operator
5
Control terminal
Note 1. The above setting operation can be performed when constant no. 02 is se-
lected. This operation is also possible when the dedicated indicator ("MODE")
is lit.
4-12
Run
switch
(contact a)
Run command (starts Inverter when "closed")
Stop command (stops Inverter when "opened")
Forward/Reverse rotation command (rotates
motor in forward direction when "opened";
rotates motor in reverse direction when "closed")
Common
0 to 5
Digital Operator (n11)
Digital Operator (n11)
Control terminal (voltage input)
Control terminal (voltage input)
Control terminal (amperage input) ON
Control terminal (amperage input) ON
Factory setting 0