Trotec DH 30 VPR+ Operating Manual

Dehumidifier / climate manager

Advertisement

Quick Links

DH 30 VPR+ / DH 60 VPR+
EN
OPERATING MANUAL
DEHUMIDIFIER / CLIMATE
MANAGER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec DH 30 VPR+

  • Page 1 DH 30 VPR+ / DH 60 VPR+ OPERATING MANUAL DEHUMIDIFIER / CLIMATE MANAGER...
  • Page 2: Table Of Contents

    Notes regarding the operating manual......... 1 Safety .................. 2 DH 30 VPR+ Information about the device.......... 4 Transport, assembly and preparation for start-up  ..... 6 Important information regarding the dehumidification http://hub.trotec.com/?id=39535 performance and drying rate .......... 8 Operation ................ 10 Errors and faults.............. 15 DH 60 VPR+ Maintenance ................ 17 Technical annex.............. 20...
  • Page 3: Safety

    • Switch the device off and disconnect the power cable from Safety the mains socket when the device is not in use. Read this manual carefully before starting or using the • Do not under any circumstances use the device if you device.
  • Page 4 Safety chapter. Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec. Residual risks Warning of electrical voltage Work on the electrical components must only be...
  • Page 5: Information About The Device

    A high humidity level in the air (starting at 70 % RH) provides Information about the device the perfect breeding ground for mould. However, the room air must not be too dry either (< 40 % RH). Materials such as Value Protection Range technology (VPR+) leather or rubber become porous, and wood becomes brittle and If properly dimensioned and operated, the dehumidifiers of the fissured.
  • Page 6: Dh 30 Vpr

    Device depiction DH 60 VPR+ DH 30 VPR+ 7, 8 7, 8 Scope of delivery • Dehumidifier • Wall holder Designation Air outlet (behind faceplate) • Air filter (combination filter) Housing • Air filter (standard) Air inlet with filter flap • Condensation drain hose, ø 5 mm (inside), l = 10 m Wall holder •...
  • Page 7: Transport, Assembly And Preparation For Start-Up

    Assembly Transport, assembly and preparation for start-up Assemble the device as follows: Always utilize the help of another person to transport and Select screw and dowel sizes suitable for the weight of the assemble the DH 30 VPR+. Always utilize the help of two other device (see technical data) and the structure of the wall.
  • Page 8 3. Remove the housing. 8. Suspend the device from the wall holder by means of the mounting brackets. Utilize the help of one or two other persons as well as suitable lifting gear to do so. 4. Mark the position for the bore holes. 9.
  • Page 9: Important Information Regarding The Dehumidification Performance And Drying Rate

    Important information regarding the Correlation between the temperature in the garage dehumidification performance and drying rate and duration of the drying process The dehumidification performance depends on: Mean temper- Approximate drying The drying period • the layout of the room ature in a gar- duration of wet can be reduced...
  • Page 10 Here a worst-case scenario: And there is another aspect: A modern car wet with rain is parked in a garage along with a Due to the minor absolute vapour pressure differences, the classic vehicle. The room temperature is 4 °C. Attributable to drops of water on the wet car do not evaporate.
  • Page 11: Operation

    Designation Operation Control dial hygrostat • Once the device has been switched on, the drying function Fusing 6.3 A / T (time delay) works fully automatically. Power Ionization button • The ionization function may be started manually as Ionizer control dial needed, see chapter Ionization.
  • Page 12 Notes regarding the condensation drain hose: Automatic defrost • The maximum pump height amounts to 10 m for the If the room temperature is lower than 15 °C, the heat exchanger DH 30 VPR+ and to 15 m for the DH 60 VPR+. will freeze during dehumidification. The device will then carry out an automatic defrost.
  • Page 13 Recommended procedure for standard treatment Procedure for intensive treatment (settings 1 - 4) In case of considerable odour nuisance – e.g. from long-lasting sources such as drains, fuel odours or the smell of mould or The perception of odours is subjective. Besides, fluctuating climate parameters such as the humidity level and room intensive one-time sources like tobacco, animal smells or musty odours in the car etc.
  • Page 14 Ozone smell Individual odour perception If used as intended and for appropriate room sizes in inhabited The odour perception and rating differs from one individual to rooms such as basements, garages, halls or libraries our ionizer another. does not produce harmful concentrations exceeding the max. Because of this individual perception, a general across-the- allowable concentration at the workplace (MAC limit value) even board recommendation for dosage and usage is not feasible,...
  • Page 15 Ozone treatment for similar applications Air filter A (highly concentrated) ozone treatment is carried out for As standard, devices of the VPR+ series are delivered with 2 air example in the professional car valeting. Especially in case of filters: pre-owned cars, unpleasant odours inside the passenger •...
  • Page 16: Errors And Faults

    • Check the power cable for damages. • Check the on-site fusing. • Have the electrics checked by a specialist company for cooling and air-conditioning or by Trotec. The device is running, but there is no formation of condensate: • Check whether the condensation drain hose is positioned correctly.
  • Page 17 Your device still does not operate correctly after these checks? Have the device repaired by authorised expert staff or by Trotec. 4. Check whether the float in the container floats. If required, fill a little water into the condensation tray. If the float is stuck and does not float, it could help to lightly tap the side of the container.
  • Page 18: Maintenance

    Maintenance intervals Maintenance Maintenance and care interval before every as needed at least every 2 at least every 4 at least every 6 at least annually start-up weeks weeks months Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt...
  • Page 19 Maintenance tasks at the electrical equipment or the air-conditioning technology must only be carried out by specialist companies for cooling and air-conditioning or by Trotec. Cleaning the housing Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture.
  • Page 20: Refrigerant Circuit

    • The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air- conditioning or by Trotec. Replacing the air filter Perform this activity every 6 months. In case of a high dust and/ or soot pollution the air filter has to be replaced after 2 months...
  • Page 21: Technical Annex

    Technical data Technical annex Parameter Value Model DH 30 VPR+ DH 60 VPR+ Dehumidification performance see dehumidification diagrams Mains connection 1/N/PE~ 230 V / 50 Hz Power cable CEE 7/7 / l = 3.5 m Power input dehumidification 0.75 kW 1.2 kW Power input ventilation 88 W 85 W Nominal/peak current...
  • Page 22 Refrigerant circuit diagram EVAPORATOR INSULATION AIR CONDENSER Operating manual – dehumidifier / climate manager DH 30 VPR+ / DH 60 VPR+...
  • Page 23: Disposal

    Disposal The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity.
  • Page 24 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...