1-5. INDOOR FAN CONTROL

1. Fan speed
( Table 5 : Indoor Fan Speed )
AB*G18LVTB
Operation mode
Heating
Cooling
Fan
Dry
Monitoring
AR*G12LLTB
Operation mode
Heating
Cooling
Fan
Dry
Monitoring
AR*G18LLTB
Operation mode
Heating
Cooling
Fan
Dry
Monitoring
*Note, during Economy operation and operation mode is Fan, air flow is 1 step downs.
(Hi > Me, Me > Lo, Lo > Quiet, Quiet > Soft Quiet)
AMP Air Conditioning
Air flow mode
Speed (rpm)
Hi
1040
Me+
1000
Me
950
Lo
800
Quiet
740
Cool air prevention
500
S-Lo
300
Hi
1040
Me
950
Lo
800
Quiet
740
*Soft Quiet
500
Auto
740
S-Lo
300
Air flow mode
Speed (rpm)
Hi
1340
Me
1240
Lo
1140
Quiet
1030
S-Lo
500
Hi
1340
Me
1240
Lo
1140
Quiet
1030
*Soft Quiet
500
Auto
1030
S-Lo
500
Air flow mode
Speed (rpm)
Hi
1380
Me
1300
Lo
1220
Quiet
1140
S-Lo
600
Hi
1380
Me
1300
Lo
1220
Quiet
1140
*Soft Quiet
600
Auto
1140
S-Lo
600
AR*G14LLTB
Operation mode
Heating
Cooling
Fan
Dry
Monitoring
www.ampair.co.uk | sales@ampair.co.uk
01-05
Air flow mode
Speed (rpm)
Hi
1560
Me
1400
Lo
1240
Quiet
1030
S-Lo
500
Hi
1560
Me
1400
Lo
1240
Quiet
1030
*Soft Quiet
500
Auto
1030
S-Lo
500