Summary of Contents for ChoiceMMed MD300C318

  • Page 1 Pluse Oximeter Instruction Manual MD300C318...
  • Page 2 Fingertip Pulse Oximeter V2.0C318 Copyright Our company owns all rights to this unpublished work and intends to maintain this work as confidential. Our company may also seek to maintain this work as an unpublished copyright. This publication is to be used solely for the purpose of reference, operation, maintenance or repair of our equipment.
  • Page 3: Safety Information

    Fingertip Pulse Oximeter V2.0C318 Safety Information Please read this manual thoroughly before using the pulse oximeter! Keep it in hand for future reference. Warnings alert the user to potential serious outcomes, such as injury or adverse events to the patient or user. Cautions alert the user to exercise care necessary for the safe and effective use of the pulse oximeter.
  • Page 4 Fingertip Pulse Oximeter V2.0C318 Prolonged use or the patient’s condition may require changing the measurement site periodically. ● Change measurement site and check skin integrity, circulatory status, and correct alignment at least every 4 hours. Follow local ordinances and recycling instructions regarding disposal or recycling of the device and ●...
  • Page 5 Fingertip Pulse Oximeter V2.0C318 Venous pulsations may cause inaccurate readings. Placement of a sensor on an extremity with a blood pressure cuff, arterial catheter, or intravascular line may cause inaccurate readings. The patient has hypotension, severe vasoconstriction, severe anemia, or hypothermia may cause inaccurate readings.
  • Page 6: Table Of Contents

    Fingertip Pulse Oximeter V2.0C318 Contents CHAPTER 1 General Information..............................7 1.1 Measuring principle................................. 7 1.2 Product Features ..................................8 1.3 Intended Use ..................................8 1.4 Appearance Introduction ................................. 9 1.5 Description of Symbols ................................. 10 CHAPTER 2 Date, Time and ID setting ............................11 2.1 ID setting....................................
  • Page 7: Chapter 1 General Information

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 1 General Information ® The pulse oximeter is integrated with Bluetooth technology allowing the user to transfer measurement data any time and anywhere. The oximeter is designed with the measurement, storage, review, audible and visible alarms, vibration alert and data transmission function (optional).
  • Page 8: Product Features

    Fingertip Pulse Oximeter V2.0C318 1.2 Product Features Compact and light weight Four display modes Low power consumption Battery low indicator Rechargeable lithium-ion battery Visible, audible and vibration alarms. Automatically power off after finger out for 8 seconds. ® Bluetooth and USB modes for data transmission. 1.3 Intended Use The Fingertip Pulse Oximeter is indicated for spot check monitoring of functional arterial oxygen saturation (SpO...
  • Page 9: Appearance Introduction

    Fingertip Pulse Oximeter V2.0C318 1.4 Appearance Introduction Fig.2 Fig.3 Description: 1: Display screen: OLED display 2: Power switch & function button Short press: press this button for about 0.5 second to power on or change the select item. Long press: Press this button for about 1.5 seconds to confirm your selection and enter into the submenu. 3:USB cable port: It is used to connect the USB cable with the pulse oximeter.
  • Page 10: Description Of Symbols

    Fingertip Pulse Oximeter V2.0C318 1.5 Description of Symbols Symbol Description Symbol Description System Set icon Power or function button Data Manage Set icon Return icon ® Bluetooth Transmission Mode Alarm Set/Alarm On icon indicator ID Set icon Battery power indicator Date and Time Set icon Power low indicator Europen union approval...
  • Page 11: Chapter 2 Date, Time And Id Setting

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 2 Date, Time and ID setting Always set the ID number, date and time before using the oximeter for the first time. Set the ID number for different users. Make sure that the date and time are correct before using the unit, reset them if necessary.
  • Page 12: Date And Time Setting

    Fingertip Pulse Oximeter V2.0C318 In figure7 long press the button to set the ID number, the range is 01 to 99. After finishing setting, short press the button to select the “Return” item and long press the button to return to the previous menu. Fig.7 Fig.8 2.2 Date and Time setting...
  • Page 13 Fingertip Pulse Oximeter V2.0C318 The displaying mode: Date: Year-Month-Day Time: Hour:Minute:Second The setting range: Year: 2008~2028 Month: 1~12 Day: 1~31 Hour: 0~23 Minute: 0~59 Second: 0~59 CAUTION: In the Date and Time setting screen, BE SURE TO select the “Return” item and long press the button to return to the previous menu.
  • Page 14: Chapter 3 Take A Measurement

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 3 Take a measurement After the ID, date and time setting. Return to the main menu and then short press the button to select the “Return” item and long press the button to confirm your selection to return to the measuring screen. Open the clamp and insert a finger into the oximeter as illustrated in the figure 11 before releasing the clamp.
  • Page 15 Fingertip Pulse Oximeter V2.0C318 The measurement screen refers to figure 13: Fig.13 Description of figure 13: 1—Time display: The current time is 22:10. 2—SpO % area of display 3—Measured SpO 4—The SpO % Plethysmograph 5—Measured pulse rate. 6—Pulse amplitude indicator. 7—Pulse rate unit .
  • Page 16 Fingertip Pulse Oximeter V2.0C318 During the measuring, each time you press the button the oximeter will switch to another display mode, there are 4 display modes shown as follows: Fig.14 Fig.15 Fig.16 Fig.17 NOTE: Please use the medical alcohol to clean the rubber touching the finger inside of Oximeter with a soft cloth dampened with 70% isopropyl alcohol, and clean the test finger using alcohol before and after each measurement.
  • Page 17: Chapter 4 Battery Charge

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 4 Battery Charge 4.1 Power Supply Battery Model: SP080 Battery Type: One 3.7V Lithium Ion Rechargeable Battery 4.2 Battery charge 4.2.1 Connect the oximeter with attached the USB cable, as shown in Fig.18. 4.2.1 Connect the other end of the USB cable with the attatched charger or a computer’s USB port. Fig.18 Fig.19 Charging temperature: 0℃~40℃...
  • Page 18 Fingertip Pulse Oximeter V2.0C318 Warning! Keep away from source of fire and/or heat. Avoiding the strongly impacting to the oximeter. Avoid the oximeter exposure straightly to the strongly sunlight. DO not leave the oximeter in the sealed car. DO NOT open or disassemble the device, opening and disassembly may cause damage to the oximeter.
  • Page 19: Chapter 5 Data Manage

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 5 Data Manage In the main menu (shown as Fig.20), select the “Data Manage” icon and long press the button to enter into Fig.21 to review, clear the data and look over the used space for data storage. Fig.20 Fig.21 Fig.22...
  • Page 20 Fingertip Pulse Oximeter V2.0C318 Clear Data: Short press the button to select the “Clear Data” item and then long press the button to conform your selection, and then the screen as shown in Fig.26 will be appear. Short press the button to select “Yes”...
  • Page 21: Chapter 6 Alarm Set

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 6 Alarm set The Alarm limits display allows you to adjust the upper and lower saturation and pulse rate limits. When the measured values exceed the setting limits, the visible, audioble or vibratory alarms will occur according to the alarm setting.
  • Page 22 Fingertip Pulse Oximeter V2.0C318 Low alarm limit setting: Fig.30 The SpO % low alarm limit range is 70% to 98%. The upper value of the SpO % low alarm limit is limited to the %upper alarm limit. The SpO % low alarm limit cannot be set equal to or higher than the SpO % upper alarm limit.
  • Page 23 Fingertip Pulse Oximeter V2.0C318 Fig.31 PR ALMHI (Upper alarm limit): Short press the button to select the “PR ALMHI” and then long press the button to increase the upper alarm limit. If you long press the button, the number will be cycled displaying. Low alarm limit setting: The pulse rate low alarm limit range is 30 to 234.
  • Page 24 Fingertip Pulse Oximeter V2.0C318 Alarm mode setting: Mode: There are three alarm modes for selection: OFF, ON and Sound Off. “OFF”: The alarm function is off, the audible, visible and vibratory alarms are ineffective. “ON”: The alarm function is on, the audible, visible and vibratory alarms are effective. “Sound Off”: The audible alarm will be ineffective, but the visible and vibratory alarms is still effective.
  • Page 25: Chapter 7 System Set

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 7 System Set ® In System Set menu, you can set the brightness of backlight, BlueTooth mode, vibration alert and so on. In the main menu short press the button to select the “System Set” item refer to figure35, and then long press the button to confirm your selection and enter into the sub menu of System Set, refer to figure 36.
  • Page 26 Fingertip Pulse Oximeter V2.0C318 Power Save: “ON” or “OFF” setting. When setting “Power save: ON”, the “BlueTooth” will be set “OFF” automatically and the beep is inefective. NOTE:If the “Power Save” is on, the display screen turns black. Long press the button return to the displaying screen, short press the button the following screen will appear showing the...
  • Page 27: Chapter 8 Data Transmission (Optional)

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 8 Data transmission (optional) Please be sure to register the pulse oximeter before transmission. Contact our company for registration. The measurement results saved in the pulse oximeter can be uploaded to a computer for review or management.
  • Page 28: Chapter 9 Specifications

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 9 Specifications Display: Display type: OLED display display range: 0~99% PR display range: 30~235 BPM PR display mode: Amplitude Bar Data update period: <15 s Resolution: %: ±1% Pulse rate: ±1BPM Measurement Accuracy: : 70%--99% ±3%; ≤69% unspecified. PR: 30~99 bpm ±2 bpm;...
  • Page 29 Fingertip Pulse Oximeter V2.0C318 Physical Characteristics: Dimensions: 56mm x 38mm x 28mm (2.2”x 1.5”x 1.1”) Weight: 51g (0.11 lbs.)(including the lithium ion battery) Battery life: Typical lithium ion battery: 300 cycles. Charge temperature: 0℃~40 (32 ℉H to 113℉H) ℃ Environment Conditions: Operating Temperature: 5℃~40℃...
  • Page 30: Chapter 10 Maintenance And Calibration

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 10 Maintenance And Calibration 10.1 Please charge the battery timely when the power low indicator flashes. 10.2 Clean the surface of the fingertip Oximeter before it is used in diagnosis for patients. 10.3 It is best to preserve the product in the environment specified in this manual. 10.4 It is recommended that the product should be kept in a dry environment anytime.
  • Page 31: Chapter 11 Troubleshooting

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 11 Troubleshooting Problem Cause Solution SpO2% or pulse Finger plugged 1.Retry by plugging the finger. rate does not correctly. 2.There is excessive illumination. display. 2. Patient’s SpO value is too 3.Measure other patients to make sure that no low to be measured.
  • Page 32: Chapter 12 Declaration

    Fingertip Pulse Oximeter V2.0C318 CHAPTER 12 Declaration FCC-ID: WWIMD300C318 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 33 Fingertip Pulse Oximeter V2.0C318 EMC of this product comply with IEC60601-1-2 standard.
  • Page 34 Fingertip Pulse Oximeter V2.0C318...
  • Page 35 Fingertip Pulse Oximeter V2.0C318...
  • Page 36 Fingertip Pulse Oximeter V2.0C318...
  • Page 37 Fingertip Pulse Oximeter V2.0C318...
  • Page 38 Fingertip Pulse Oximeter V2.0C318 Manufacturer: Beijing Choice Electronic Technology Co., Ltd. Address: Rm. 1127-1128, Fuxing Road, A36, Bailangyuan Building B, 100039, Beijing, People’s Republic of China. Tel: (+86)10- 88204188、68221006 、88203520 Fax: (+86)10-88204632 www.choicemmed.com...