Bbm Specifications; On-Board Battery; Battery Charge Life (Data Retention; Module Dimensions - Mylex AcceleRAIDTM 352 PCI to Ultra 160 SCSI RAID Controller AcceleRAID 352 Installation Manual

Pci to ultra 160 scsi raid controller
Table of Contents

Advertisement

BBM Specifications

On-board Battery

Electrical Properties
• One Lithium-Ion cell, 4.1 V @ 900mAH
Physical Description
• Nominal pack size (in inches): 1.55(L) x 1.55(W) x 0.375 (H)

Battery Charge Life (Data Retention)

Under typical conditions (35ºC) minimum specified backup
duration
Approximately 168 hours with 32MB
Approximately 110 hours with 64MB
Approximately 60 hours with 128MB
Under less than typical conditions (45ºC) minimum specified
backup duration
Approximately 144 hours with 32MB
Approximately 96 hours with 64MB
Approximately 48 hours with 128MB

Module Dimensions

Length:
Width:

Environmental

Temperature
Storage:
Humidity
Non-operating:

Warranty

1 1/2-Year, on the battery
Manual No. 775051
5.85 inches
3.5 inches
Operating:
Operating:
BBM-Battery Backup Module
0ºC to +45ºC
(+32ºF to +113ºF)
-40ºC to +60ºC
(-40ºF to +140ºF)
10% to 90%
relative humidity (non-condensing)
10% to 90%
relative humidity (non-condensing)
A-5