Motor Driver IC Replacement for Socketed MCBs

VL Part No: 85.3773.0002
Repair/Replacement Procedure
Note: To improve reliability, Vari-Lite has introduced main control boards (MCB) with the motor
drivers mounted directly on the board. Drivers cannot be replaced on these boards. For boards with
sockets, to remove a motor driver IC, you will need a Static-Dissipative PLCC Extractor tool. This tool
is available from Stanley Supply & Services (part number: 126-453).
Step 1. Disconnect luminaire AC input cable from power source.
CAUTION: Always use anti-static precautions when working with PCBs.
ESD
Step 2. Remove Main Control Board PCB following procedure on
Step 3. Remove heatsink from Main Control Board PCB. If thermal compound is used, remove and
replace with thermal pad (Vari-Lite part number: 10.9678.0885, Thermal Transfer Kit)
Step 4. Using C.K. PLCC extractor tool (see above), replace required stepper motor driver (loca-
tions: U27-U30, U32-U44).
Step 5. Reinstall Main Control Board PCB performing Steps 2-6 in reverse order from
28
ERVICE
Stepper Motor Drivers (locations: U27-U30, U32-U44)
Figure 2-10: VL3000 Series Motor Drivers on Main Control Board